Viessmann SCU224 Manuel de service

Naviguer en ligne ou télécharger Manuel de service pour Mesure, test et contrôle Viessmann SCU224. Viessmann SCU224 Technical data Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
SCU224
Manual
en-US/CA
SCU224
Mounting
Connection
Application examples
Operation
Troubleshooting
Thank you for buying this product.
Read this manual carefully to get the best perfomance from this unit.
Please keep this manual carefully.
5443203 v1.0 02/2010
*49011100*
49011100
Vue de la page 0
1 2 3 4 5 6 ... 51 52

Résumé du contenu

Page 1 - *49011100*

SCU224Manual en-US/CASCU224MountingConnectionApplication examplesOperationTroubleshootingThank you for buying this product.Read this manual carefully

Page 2 - Contents

© Viessmann 5443203| 10SCU224∆T control for the heat exchange between 2 tanksDT3O:Switch-on temperature diff. Adjustment range: 2.0 ... 40.0°Ra [1.0

Page 3 - Overview

© Viessmann 544320311 |SCU224Maximum temperature limitationMX3O / MX3F:Maximum temperature limitation Adjustment range: 30.0 ... 200.0 °F [0.0 ... 95.

Page 4 - 1. Installation

© Viessmann 5443203| 12SCU224R2S1S2R1S3S4 / TRSystem layout 3The controller calculates the temperature difference bet-ween collector sensor S1 and tan

Page 5 - S1 S2 S3

© Viessmann 544320313 |SCU224Adjustment ChannelsChannel Description Factory setting PageArr x System 3 39DT O x Switch-on temperature difference 12.0

Page 6

© Viessmann 5443203| 14SCU224The thermostat function works independently from the solar operation and can be used for using surplus energy or for back

Page 7

© Viessmann 544320315 |SCU224When a starting time for thermal disinfection with starting delay is adjusted in SDIS, the thermal disinfection will be d

Page 8

© Viessmann 5443203| 16SCU224System layout 4S2R1S3R2S1The controller calculates the temperature differences between collector sensor S1 and tank sen

Page 9

© Viessmann 544320317 |SCU224Adjustment ChannelsChannel Description Factory setting PageArr x System 4 39nMN x Minimum pump speed 30 %39DT1O x Switch-

Page 10 - © Viessmann 5443203

© Viessmann 5443203| 18SCU224System layout 5The controller calculates the temperature differences between collector sensor S1 and tank sensors S2 an

Page 11

© Viessmann 544320319 |SCU224Legend:Symbol Specificationx Channel is availablex* Channel is available if the corresponding option is activated.Adjustme

Page 12

© Viessmann 5443203| 2SCU224Safety advice:Please read the following information carefully before installing and operating the controller. In this way

Page 13 - Symbol Specification

© Viessmann 5443203| 20SCU224S1S2S3R1 R2System layout 6The controller calculates the temperature differences between collector sensor S1 and tank se

Page 14

© Viessmann 544320321 |SCU224Legend:Symbol Specificationx Channel is availablex* Channel is available if the corresponding option is activated.Adjustme

Page 15

© Viessmann 5443203| 22SCU224System layout 7The controller calculates the temperature differences between the collector sensors S1 and S3 and the ta

Page 16

© Viessmann 544320323 |SCU224Legend:Symbol Specificationx Channel is availablex* Channel is available if the corresponding option is activated.Adjustme

Page 17

© Viessmann 5443203| 24SCU224S1S4S2S3R1R2System layout 8The controller calculates the temperature difference bet-ween collector sensor S1 and tank sen

Page 18

© Viessmann 544320325 |SCU224Legend:Symbol Specificationx Channel is availablex* Channel is available if the corresponding option is activated.s Channe

Page 19

© Viessmann 5443203| 26SCU224∆T control for backup heating by solid fuel boilerDT3O:Switch-on temperature diff. Adjustment range: 2.0 ... 40.0°Ra [1.

Page 20

© Viessmann 544320327 |SCU224Maximum temperature limitationMX3O / MX3F:Maximum temperature limitation Adjustment range: 30.0 ... 200.0 °F [0.0 ... 95.

Page 21

© Viessmann 5443203| 28SCU224S1S3S2S4R2R1System layout 9The controller calculates the temperature difference bet-ween collector sensor S1 and tank sen

Page 22

© Viessmann 544320329 |SCU224Legend:Symbol Specificationx Channel is availablex* Channel is available if the corresponding option is activated.s Channe

Page 23

© Viessmann 54432033 |SCU224!• System-monitoring-display• Up to 4 Pt1000 temperature sensors• 2 semiconductor relays for pump speed control• 10

Page 24

© Viessmann 5443203| 30SCU224System layout 10Arr 10VBus109The controller calculates the temperature difference bet-ween collector sensor S1 and tank s

Page 25

© Viessmann 544320331 |SCU224Legend:Symbol Specificationx Channel is availablex* Channel is available if the corresponding option is activated.s Channe

Page 26

© Viessmann 5443203| 32SCU224The system monitoring display consists of three blocks: channel display, tool bar and system screen (active

Page 27

© Viessmann 544320333 |SCU224The system screen (active system layout) shows the system selected on the controller. It consists of several system compo

Page 28

© Viessmann 5443203| 34SCU2243. Commissioning Î Establish the power supply During a short initialization phase, the operating control lamp flashes red

Page 29

© Viessmann 544320335 |SCU224Overview of system layouts:Arr 1 : standard solar system layoutArr 2 : solar system layout with heat exchangeArr 1 Arr

Page 30

© Viessmann 5443203| 36SCU224Now the controller is ready for operation with typical settings to suit the selected system layout. The settings made in

Page 31

© Viessmann 544320337 |SCU224Indication of collector temperaturesIndicates the current collector temperature.• COL : collector temperature (1-colle

Page 32 - 2. Operation and function

© Viessmann 5443203| 38SCU224TimeIndicates the actual time. Press the button for two seconds in order to adjust the hours. Press it again in order

Page 33 - 2.3 Flashing codes

© Viessmann 544320339 |SCU224∆T-regulationDT O / DT1O / DT2O / DT3O:Switch-on temperature diff. Adjustment range: 2.0 ... 40.0°Ra [1.0 ... 20.0 K]in

Page 34 - 3. Commissioning

© Viessmann 5443203| 4SCU224displaypush buttonfuse 4Acable conduits with strain reliefcover1.1 MountingThe unit must only be installed • in a dry inte

Page 35

© Viessmann 5443203| 40SCU224Maximum tank temperature Once the adjusted maximum temperature is exceeded, the solar pump is switched off and furt

Page 36

© Viessmann 544320341 |SCU224CMX / CMX1 / CMX2: Maximum collector temp. Adjustment range:150 ... 320 °F[70 ... 160 °C]in steps of 1 °Ra [1 K] Factor

Page 37 - 4. Channel overview

© Viessmann 5443203| 42SCU224CMN / CMN1 / CMN2:Collector minimum temp. Adjustment range: 50 ... 190 °F[10 ... 90 °C]in steps of 1 °Ra [0.5 K]Factory s

Page 38

© Viessmann 544320343 |SCU224The SCU224 priority logicPRIO: Loading priority Adjustment range: SE 1, SE 2, Su 1, Su 2, 0, 1, 2 Factory setting: Arr 4

Page 39 - 4.2 Adjustment channels

© Viessmann 5443203| 44SCU224Evacuated tube collector functionO TC:Evacuated tube collector function Adjustment range: OFF / ON Factory setting: OFFNo

Page 40

© Viessmann 544320345 |SCU224Time period - switch-on conditionstDTO: Time period - switch-on conditions Adjustment range: 1 ... 100 sin steps of 1 s

Page 41 - and (flashing)

© Viessmann 5443203| 46SCU224For control and service work, the operating mode of the controller can be manually adjusted. For this purpose, select the

Page 42 - , and

© Viessmann 544320347 |SCU2245. TroubleshootingOperating control lampWarning symbolsOperating control lamp flashes red. On the display the symbols a

Page 43

© Viessmann 5443203| 48SCU2245.1 Various:Pump starts for a short moment, switches off, switches on again, etc. Temperature difference at the controlle

Page 44

© Viessmann 544320349 |SCU224Tanks cool down at nightCollector circuit pump runs during the night?no yesCheck controller:Manual operation active?Tube

Page 45

© Viessmann 54432035 |SCU2241.3 Data communication/ BusThe controller is equipped with a VBus® for data transfer with and energy supply to external mo

Page 46

© Viessmann 5443203| 50SCU2246. AccessoriesSmart Display SD3The Smart Display is designed for simple connection to controllers with VBus®. It is used

Page 47 - 5. Troubleshooting

© Viessmann 544320351 |SCU224Notes

Page 48 - 5.1 Various:

© Viessmann 5443203| 52SCU224Please note:The design and the specifications can be changed without prior notice.The illustrations may differ from the or

Page 49

© Viessmann 5443203| 6SCU224S1S2S4 / TRSystem layout 1The controller calculates the temperature difference bet-ween collector sensor S1 and tank senso

Page 50 - 6. Accessories

© Viessmann 54432037 |SCU224Legend:Symbol Specificationx Channel is availablex* Channel is available if the corresponding option is activated.s* System

Page 51

© Viessmann 5443203| 8SCU224S1S3S4R1R2S2System layout 2The controller calculates the temperature difference bet-ween collector sensor S1 and tank sens

Page 52

© Viessmann 54432039 |SCU224Legend:Adjustment ChannelsChannel Description Factory setting PageArr x System 2 39DT O x Switch-on temperature difference