Vue de la page 0
IMPORTANT
KRT 150 to KRT 540
Wood Fired Boiler
Maximum output: 150 to 540 kW / 512 to 1843 MBH
Minimum output: 45 to 140 kW / 154 to 478 MBH
Assembly and Installation Instructions
KÖB IS A PART OF THE VIESSMANN GROUP.
Pyrot ai/ii 11/2008
Vue de la page 0
1 2 3 4 5 6 ... 48 49

Résumé du contenu

Page 1 - Wood Fired Boiler

IMPORTANT KRT 150 to KRT 540 Wood Fired Boiler Maximum output: 150 to 540 kW / 5

Page 2

10 and regulations) these being separate items for the scope of delivery ordered from Viessmann according to the de-scriptio

Page 3

11 8.3 Inspection of the installation Before the commissioning, the future operating organisa-tion along with the installing companie

Page 6

a) Note: - To reliably prevent boiler corrosion caused by condensation of flue gases, the boiler return flow temperature must not under

Page 7 - 3.2 The chimney connection

Mixing valves: North America boiler model 3-way mixing valve mixing valve actuator KRT- Viessmann Viessmann diameter part no. part

Page 8 - 5 Water System Installation

a) Fire-extinguishing System for Burner Slide-in Module, Art. No. K-SLE Note: Pyromat-DYN has an extra charge with Art. No. K-SLE (see Sp

Page 9 - 7 Fire Protection

Spec Sheet Fire- extinguishing Systems K-SLE & K-SLV Installation vIESmAnn 4550-2

Page 10 - 8 Commissioning

Spec Sheet Fire- extinguishing Systems K-SLE & K-SLV Installation vIESmAnn 4550-3

Page 11 - 4 Commissioning and handover

Description: The PYROT Rotation Heating System (patent no: EP 0 905 442 B1) was developed for automatic incineration of all dry to moist wo

Page 12

2 Safety, Installation and Warranty Requirements Please ensure that’ these instructions are read and understood before commencing installation. F

Page 13 - Installation, closed system

Technical specs: PYROT Rotation Heating system Trade name 150 220 300 400 540 Item No: KRT-150 KRT-220 KRT-300 KRT-400 KRT-540 Perfor

Page 14 - Spec Sheet

Spec Sheet Pyrot Rotation Heating System Boiler Plant vIESmAnn 6010-3

Page 15

Connections / dimensions: Ptrtec [Item-Nr.] KRT-150 KRT- 220 KRT-300 KRT-400 KRT-540 Water connection PN 6 (see Spec Sheet 6960) l B

Page 16 - Fire- extinguishing Systems

Description: Exhaust gas de-duster 90 liters [24 USG], [Item no. KRT-E…-1] The exhaust gas de-duster is for minimizing dust emissions an

Page 17

Dimensions and data: Exhaust flue gas de-duster PYROT [ITEM NO] KPR-E150-1 KPR-300-1 KPR-E400-1 KPR-E540-1 A [in] / [mm] 7.9 / 20

Page 18

Description: De-ashing in Ash Bin 240 liters [63.5 USG], [Item No. KRT-A2-S] De-ashing in Ash Skip, 800 liters [211.3 USG], [Item No. KRT

Page 19 -

Description: De-ashing in Base Container [Item No. KRT-ES-100-S] De-ashing in Base Container [Item No. KRT-ES-150-S] De-ashing in Base Co

Page 20

Description: Pneumatic Cleaning System [Item No. KRT-W100-S] Pneumatic Cleaning System [Item No. KRT-W150-S] Pneumatic Cleaning System [I

Page 21 - Boiler Plant

PYROT – Vitocontrol-C A microprocessor control system for the complete PYROT Boiler Plant, incl. control of the systems for the fuel loadi

Page 22 - Connections / dimensions:

Extensions available for the PYROT Vitocontrol-C Control System (Article ECO-…) at an extra charge: PYROT Single-unit System: Designatio

Page 23

Safety, Installation and Warranty Requirements  Fiberglass wool and ceramic fiber Materials The state of California has listed the airborne fiber

Page 24

Triggering System for external drive [Art. No. ECO-A10] Function: Starttec motor starter for optimized connection of an external conveyor

Page 25

Note: The control system components below are reserved for the PYROT Single-unit System. With the PYROT Double-unit System, these function

Page 26

Mastercontrol [Art. No. ECO-M1] Mastercontrol improves the overall generation of heat by two biomass boilers (PYROT double-unit system), in

Page 27

Extensions available for the Mastercontrol (article ECO-M1) at an extra charge: Designation

Page 28 - Pyrot - Vitocontrol

Control Module with Extended Control System [Art. No. ECO-BM-00] The ECOTRONIC is a decentralized microprocessor system in which various

Page 29

Controller for Heat Generator, single [Art. No. ECO-KE] Immediately after heat is taken from the accumulator to cover a heat requirement

Page 30

Parallel heat generator control [Art.-No.: ECO-KP0] The additional heat generator designed as a hydraulic switch supplies heat to the s

Page 31

Controller for Room Heating Units [Art. No. ECO-H] A weather-guided heating control system with a digital timer for lower able operation a

Page 32

Controller for Air Handling Unit Group [Art. No. ECO-L] The burner storage system supplies the air heaters with maximum flow temperature.

Page 33

Controller for Solar Domestic Water Heater [Art. No. ECO-S1] For use in simple solar facilities as a single control circuit for heating t

Page 34

4 Contents 1 General Information 6 1.1 State of the art 6 1.2 Documented information 6 2 Codes 6 2.1 M

Page 35

Spec Sheet ECOTRONIC Heating Control Unit Solar Energy vIESmAnn 4050-2

Page 36

Visualization of Pyromat Internally [ECO-VIM] Visualization of Pyrot Internally [ECO-VIR] All the data is conducted to the PC by a data t

Page 37

Arrangement of the electrical wiring on the Pyrot (Recommendation for the electrician; not included in the scope of delivery) vIESmAnn 1/

Page 38

Installation (one fitter with helper provided by the customer) [Art. No. IMO-1] Performance provided by the contractor (supplier): Furni

Page 39 - Solar Energy

Installation (two KÖB fitters) [Art. No. IMO-2] Performance provided by the contractor (supplier): Furnishing the entire scope of the de

Page 40

A prerequisite for approval is the express permission for such by the public authority responsible. For claims to the warranty according to

Page 41

5) Bulk density S (kg/m³), water content W (%), size G (mm) Bulk density S in kg/m³ (lb/ft3), water content W in %, size C1, C3,

Page 42

Attachment B TERMS AND CONDITIONS OF SALE, DELIVERY AND PAYMENT GENERAL PROVISIONS 1. (a) This agreement, performances of contract and quot

Page 43 - 1120/b-1

5302 630 08/08 Printed in Canada sold and delivered and to seize the same wherever the same may be located at any time of day or night or to

Page 44 - 1120/b-2

Viessmann Manufacturing Company (U.S.) Inc. 45 Access Road Warwick, Rhode Island 02886 USA Tel. (401) 732-0667 Fax (401) 73

Page 45

5 9 Spec Sheets 6960-1, 2, 3 PYROT rotary combustion chamber boiler, Installation of Closed System 4550-1, 3 Extinguishing System, I

Page 46 - 1010-d-2

6 1 General Information Viessmann solid-fuel boiler may only be set up and com-missioned by specialists. This will rule out any incorre

Page 47

7 3 The structural Surroundings for the Boiler The national building regulations existing in this connection must always be complied with. 3

Page 48

8 5 Water System Installation Customers must ensure that there is a supply of water in-dependent of the electricity supply. This (redund

Page 49

9 6 Electrical Installation 6.1 Positioning the control module and control cabinet Electrical company at a place easily accessible for