Installation andOperating Instructionsfor use by engineers and heating contractors5603 882 - 01 07/2014Read and save these instructionsfor future ref
105603 882 - 01Pyrotec Installation & OperatingGeneral InformationMeasurements for the combustion chamber as standard delivery conditionBoiler mod
115603 882 - 01 Pyrotec Installation & Operating Wood Fuel RequirementsAllowed fuels- Forest wood and plantation wood (complete untreated trees
125603 882 - 01Pyrotec Installation & Operating Wood Fuel Requirements (continued)General InformationSaw dustFuel code Bulk Density kg/m³ [lb/ft³]
135603 882 - 01 Pyrotec Installation & Operating Wood Fuel Requirements (continued)If fuel does not comply with these limits, there is a risk of
145603 882 - 01Pyrotec Installation & OperatingSafety Carbon MonoxideCAUTIONDo not use this boiler if any part has been under water. Immediately c
155603 882 - 01 Pyrotec Installation & OperatingWARNINGInhaling of fiberglass wool and/or ceramic fiber materials is a possible cancer hazard. Th
165603 882 - 01Pyrotec Installation & OperatingSafetyPower Failure ProvisionThe PYROTEC Grate Firing System is equipped with a flue gas exhaust bl
175603 882 - 01 Pyrotec Installation & OperatingSafety Mechanical RoomNo temperature-sensitive pipes or lines may be installed in the floor benea
185603 882 - 01Pyrotec Installation & OperatingWARNINGIncorrect ambient conditions can lead to damage to the heating system and put safe operation
195603 882 - 01 Pyrotec Installation & OperatingCodesProvision for combustion and ventilation air must be made in accordance with applicable loca
25603 882 - 01Pyrotec Installation & Operating Safety, Installation and Warranty RequirementsWARNINGInstallers must follow local regulations with
205603 882 - 01Pyrotec Installation & Operating Technical DataBoiler model KPT- 390 530 720 950 1250Maximum outpu
215603 882 - 01 Pyrotec Installation & OperatingMechanicalSpecifications Boiler DimensionsDimensionsBoiler Model KPT- 390 530 720 950
225603 882 - 01Pyrotec Installation & OperatingabDimensionsBoiler Model KPT- 390 530 720 950 1250a in. (mm)1293/16 (3282) 149 (3782) 1
235603 882 - 01 Pyrotec Installation & Operatingfrom the furnaceto the chimneyfrom the furnaceto the chimneyEFDGTopMechanical Flue Gas CycloneBoi
245603 882 - 01Pyrotec Installation & Operating Recirculation SystemMechanical
255603 882 - 01 Pyrotec Installation & OperatingItem Boiler Model KPT- 390 530 720 950 1250no. Description Quantity Quantity Quantity Quantity Qu
265603 882 - 01Pyrotec Installation & Operating1. Install the pressure relief valve, discharge pipe, air vent and pressure gauge as illustrated
275603 882 - 01 Pyrotec Installation & OperatingMechanical Safety Devices (continued)BCDFGHJKLMOPEIARQSTUIIINP Pressure relief valve, 30 psi or 6
285603 882 - 01Pyrotec Installation & OperatingDrain inspection portSystem fillSystem fillSafety heat exchanger top view4 heat exchanger loops and
295603 882 - 01 Pyrotec Installation & OperatingMechanicalCustomer supplied:- PDP Pressure relief valve drain pipe- DCW Cold water inlet, min.
35603 882 - 01 Pyrotec Installation & Operating About These InstructionsTake note of all symbols and notations intended to draw attention to pote
305603 882 - 01Pyrotec Installation & Operating Piping and Installation of Safety Devices (continued)Mixing valve Viessmann ASME recommended tank
315603 882 - 01 Pyrotec Installation & OperatingMechanicalBack-burn safeguard for the fuel supply systemThe fire extinguishing system for the con
325603 882 - 01Pyrotec Installation & Operating Fire Extinguishing SystemLegendA CombustionB Metering ContainerC Fuel supplyD Extinguishing wa
335603 882 - 01 Pyrotec Installation & OperatingMechanical Assembly of the Fire Extinguishing SystemItem No. Quantity Description1 1 Floater swit
345603 882 - 01Pyrotec Installation & Operating Assembly of the Fire Extinguishing System (continued)The following assembly instructions for the f
355603 882 - 01 Pyrotec Installation & OperatingCAUTIONThe information about wire type, wire number and wire gauge made in the wiring diagrams is
365603 882 - 01Pyrotec Installation & Operating Control Panel (continued)Vitocontrol - C, Pyrocontrol KPTMains supply 208V, 3 phase, 60 Hz, see fi
375603 882 - 01 Pyrotec Installation & OperatingElectrical Control Panel (continued)Device tags and designations may vary from project to project
385603 882 - 01Pyrotec Installation & Operating Electrical ComponentsElectrical
395603 882 - 01 Pyrotec Installation & OperatingElectricalHigh VoltageNumber Designation Device tag Description1 M1 -3M1 Flue gas exhaust blower
45603 882 - 01Pyrotec Installation & OperatingTable of ContentsIntroductionGeneral Information SafetyMechanicalSafety, Insta
405603 882 - 01Pyrotec Installation & OperatingElectricalNumber Designation Device tag DescriptionAM9 -9 M9 Motor for rotary valveRotary Valve Fue
415603 882 - 01 Pyrotec Installation & OperatingIn-feed augerNumber Designation Device tag Description40 M2 -4M2 Motor for in-feed auger41 S2 -68
425603 882 - 01Pyrotec Installation & Operating Fuel Transport and Extraction Systems (continued)Pellet extraction augerNumber Designation Device
435603 882 - 01 Pyrotec Installation & OperatingElectrical Fuel Transport and Extraction Systems (continued)Horizontal extraction systemNumber De
445603 882 - 01Pyrotec Installation & OperatingHydraulic unitNumber Designation Device tag Description71 M6 -7M6 Motor for hydraulic unit72 Y6.1 -
455603 882 - 01 Pyrotec Installation & OperatingElectrical Thermal Storage TankThermal storage tankNumber Designation Device tag Description84 B2
465603 882 - 01Pyrotec Installation & Operating Boiler WiringCAUTIONThe information about wire type, wire number and wire gauge made in the wiring
475603 882 - 01 Pyrotec Installation & OperatingOperation CommissioningInitial startupOnly a Viessmann or another trained specialist may put a n
485603 882 - 01Pyrotec Installation & OperatingWhen storage facilities for wood are required, the wood should be kept at least 5 ft. (1.5 m) from
495603 882 - 01 Pyrotec Installation & OperatingOperationExcess temperature/power failureCAUTIONDANGER OF THIS EQUIPMENT SUDDENLY GOING UP IN FLA
55603 882 - 01 Pyrotec Installation & OperatingTable of ContentsMechanical (continued)ElectricalOperationPageFire Extinguishing System...
505603 882 - 01Pyrotec Installation & Operating Pyrocontrol Control SystemThe control system for the Pyrotec boiler firing process (Pyrocontrol) i
515603 882 - 01 Pyrotec Installation & OperatingOperation Pyrocontrol Control System (continued)Touch screen, Screen 1-8The touch screen is 6¼ in
525603 882 - 01Pyrotec Installation & Operating Pyrocontrol Control System (continued)The following applies to all screens. The screen title and u
535603 882 - 01 Pyrotec Installation & OperatingOperation Pyrocontrol Control System (continued)Screen 2, Alarm listTouching the red Alarm line s
545603 882 - 01Pyrotec Installation & Operating Pyrocontrol Control System (continued)Screen 3, Managing the user statusTouching the soft touch ke
555603 882 - 01 Pyrotec Installation & OperatingOperation Pyrocontrol Control System (continued)Screen 4, Adjusting settings and process paramete
565603 882 - 01Pyrotec Installation & Operating Pyrocontrol Control System (continued)Screen 7, Overview, wood-powered boilerTouching the KÖB Boil
575603 882 - 01 Pyrotec Installation & OperatingOperation Pyrocontrol Control System (continued)Screen 8, Additional boilersWhen the soft touch k
585603 882 - 01Pyrotec Installation & OperatingPyrotec control system parameterParameters boiler Unit Min. Max. Default Detailed definition1 Boile
595603 882 - 01 Pyrotec Installation & OperatingOperation Pyrocontrol Control System (continued)Pyrotec controller parameter reference guide for
65603 882 - 01Pyrotec Installation & Operating Important Regulatory and Installation Requirements Take note of all symbols and notations intended
605603 882 - 01Pyrotec Installation & Operating Pyrocontrol Control System (continued)Pyrotec controller parameter reference guide for the technic
615603 882 - 01 Pyrotec Installation & OperatingOperation Pyrocontrol Control System (continued)Pyrotec controller parameter reference guide for
625603 882 - 01Pyrotec Installation & Operating Operating ModesThe following terms are displayed in the operating mode line depending on the situa
635603 882 - 01 Pyrotec Installation & OperatingOperationFull load operationAs soon as a combustion chamber temperature of approximately 356° F (
Filling the burner troughWhen the system has been switched off properly, there is no more fuel in the burner trough or in the underfeed auger.With the
75603 882 - 01 Pyrotec Installation & OperatingGeneral Information Product InformationViessmann solid-fuel boiler may only be installed and servi
85603 882 - 01Pyrotec Installation & Operating Boiler DescriptionDescriptionThe PYROTEC Grate Firing System (patent no: EP 0 905 442 B1) was devel
95603 882 - 01 Pyrotec Installation & Operating Transport and InstallationGeneral InformationPrecautions must be taken to avoid accidents and inj
Commentaires sur ces manuels