Installation Instructions
Rigid Pipe Venting Systems
5547 909 - 05 04/2015
for use by heating contractor
Vitodens 100-W WB1B Series,
Vitodens 200-W WB2B Series,
Vitodens 200-W B2HA/ B2HB Series and
Vitodens 222-F B2TA/ B2TB Series
(with preinstalled coaxial vent pipe adaptor)
Read and save these instructions
for future reference.
Please file in service binder
Product may not be exactly as shown
IMPORTANT
Vue de la page 0
1 2 3 4 5 6 ... 95 96

Résumé du contenu

Page 1 - Installation Instructions

Installation InstructionsRigid Pipe Venting Systems5547 909 - 05 04/2015for use by heating contractorVitodens 100-W WB1B Series, Vitodens 200-W WB2B

Page 2 - Introduction

105547 909 - 05Rigid Venting Systems Installation About These Installation InstructionsTake note of all symbols and notations intended to draw attenti

Page 3 - Table of Contents

115547 909 - 05Rigid Venting Systems InstallationGeneral Information General Installation InformationWARNINGEnsure that the entire venting system is p

Page 4 - (Two-pipe System)

125547 909 - 05Rigid Venting Systems Installation General Installation Information (continued)Recommended venting practiceWhen installing a venting sy

Page 5 - (Room Air Dependent)

135547 909 - 05Rigid Venting Systems InstallationGeneral Information General Installation Information (continued)Fig. 3 Boiler models Vitodens 200-W

Page 6 - Componentry (System Options)

145547 909 - 05Rigid Venting Systems Installation Side Wall Venting Layouts (Coaxial)Layout with basic coaxial vent componentryFig. 4 Standard side wa

Page 7

155547 909 - 05Rigid Venting Systems InstallationSide Wall Vent Installation (Coaxial) Side Wall Venting Layouts (Coaxial) (continued)Fig. 5 Side wal

Page 8

165547 909 - 05Rigid Venting Systems Installation Side Wall Venting Layouts (Coaxial) (continued)Fig. 6 Side wall venting layout For Vitodens WB2B b

Page 9 - Common Venting

175547 909 - 05Rigid Venting Systems InstallationSide Wall Vent Installation (Coaxial) Component Installation GuideFig. 7 Coaxial vent termination Le

Page 10 - IMPORTANT

185547 909 - 05Rigid Venting Systems Installation Component Installation Guide (continued)Protective screenDimensionsabc12 in. (305 mm) must be at lea

Page 11

195547 909 - 05Rigid Venting Systems InstallationSide Wall Vent Installation (Coaxial) 8...underneath a veranda, porch or deck, unless: the veranda,

Page 12 - General Information

25547 909 - 05Rigid Venting Systems Installation Safety, Installation and Warranty RequirementsIntroductionPlease ensure that these instructions are r

Page 13

205547 909 - 05Rigid Venting Systems Installation Installation of Anchoring SystemFig. 11 The venting system must be securely supported by an anchori

Page 14

215547 909 - 05Rigid Venting Systems InstallationSide Wall Vent Installation (Coaxial) Vent Length RequirementsMaximum vent lengthTable 5. Standard si

Page 15 - 5547 909 - 05

225547 909 - 05Rigid Venting Systems Installation Vent Length Requirements (continued)Side Wall Vent Installation (Coaxial) For maximum equivalent ve

Page 16

235547 909 - 05Rigid Venting Systems Installation Vent Length Requirements (continued)Fig. 14 Vitodens 100-W, WB1B, Vitodens 200-W, WB2B, Vitodens 22

Page 17 - Component Installation Guide

245547 909 - 05Rigid Venting Systems Installation Vertical Venting Layouts (Coaxial)Layout of Vertical Vent systems with accessoriesSelect from the ve

Page 18

255547 909 - 05Rigid Venting Systems Installation Vertical Venting Layouts (Coaxial) (continued)General installation examples Ensure that the venting

Page 19

265547 909 - 05Rigid Venting Systems Installation Component Installation GuideCoaxial vent termination installationVertical vent termination installat

Page 20

275547 909 - 05Rigid Venting Systems InstallationVertical Vent Installation (Coaxial) Component Installation Guide (continued)Flashing and storm colla

Page 21 - Vent Length Requirements

285547 909 - 05Rigid Venting Systems Installation Installation of Support SystemThe venting system must be securely supported by a support system suit

Page 22

295547 909 - 05Rigid Venting Systems InstallationVertical Vent Installation (Coaxial) Vent Length RequirementsBoiler model a (max. length)B2TA 19, 35B

Page 23 - Minimum vent length

35547 909 - 05Rigid Venting Systems InstallationTable of Contents PageSafety, Installation and Warranty Requirements...2 How these Insta

Page 24

305547 909 - 05Rigid Venting Systems InstallationVertical Vent Installation (Coaxial) Vent Length Requirements (continued)Maximum vent length with inc

Page 25

315547 909 - 05Rigid Venting Systems Installation Vent Length Requirements (continued)Equivalent vent length calculation exampleTable 13 Type of fitti

Page 26

325547 909 - 05Rigid Venting Systems InstallationVertical Vent Installation (Coaxial) Component Parts of the Venting SystemHorizontal vent termination

Page 27

335547 909 - 05Rigid Venting Systems Installation Component Parts of the Venting System (continued)Vent system dimensionsBoiler model a in. (mm)bin. (

Page 28

345547 909 - 05Rigid Venting Systems Installation Direct Venting Options (Two-pipe System) Fig. 30 Single or two-pipe installationLegendA Combustion a

Page 29

355547 909 - 05Rigid Venting Systems Installation Exhaust Vent/Air Intake RequirementsCombustion Air Supply The Vitodens boiler is suitable for sidewa

Page 30

365547 909 - 05Rigid Venting Systems InstallationGeneral requirementsThe Vitodens 100-W, 222-F and 200-W boilers must be located in such a way that th

Page 31

375547 909 - 05Rigid Venting Systems InstallationDirect Venting (Two-pipe System) General Installation InformationInstallation steps (outline)Exhaust

Page 32

385547 909 - 05Rigid Venting Systems Installation General Installation Information (continued)Table 16. Approved materials for two-pipe systemPart Mat

Page 33

395547 909 - 05Rigid Venting Systems InstallationDirect Venting (Two-pipe System) General Installation Information (continued)8...underneath a verand

Page 34

45547 909 - 05Rigid Venting Systems InstallationTable of ContentsVertical Vent Installation (Coaxial) (continued)Direct Venting (Two-pipe System)Vent

Page 35

405547 909 - 05Rigid Venting Systems Installation Vent Requirements - Stainless SteelIMPORTANTFor exhaust vent pipe material:Do not use any other vent

Page 36

415547 909 - 05Rigid Venting Systems InstallationDirect Venting (Two-pipe System) Vent Requirements - Stainless Steel (continued)Additional requiremen

Page 37

425547 909 - 05Rigid Venting Systems Installation Vent Requirements - Stainless Steel (continued)Additional requirements for stainless steel vent pipe

Page 38

435547 909 - 05Rigid Venting Systems InstallationDirect Venting (Two-pipe System) Vent Requirements - Stainless Steel (continued)Additional requiremen

Page 39

445547 909 - 05Rigid Venting Systems Installation Component Parts of the Venting System - Stainless SteelFig. 36 Termination Coupling with ScreenFig.

Page 40

455547 909 - 05Rigid Venting Systems InstallationDirect Venting (Two-pipe System) Vent Requirements - CPVCAdditional requirements for UL/ULC listed CP

Page 41

465547 909 - 05Rigid Venting Systems Installation Requirements for UL/ULC Listed Rigid PP(s) Vent Pipe MaterialThe venting system must be installed by

Page 42 - 16 in. (327 mm)

475547 909 - 05Rigid Venting Systems InstallationDirect Venting (Two-pipe System) Vent and Air Intake Pipe Starter Adaptors - CPVCWARNING(For this typ

Page 43

485547 909 - 05Rigid Venting Systems Installation Vent and Air Intake Pipe Starter Adaptors - CPVC (continued)LegendA Air intake, max. insertion 2½ in

Page 44

495547 909 - 05Rigid Venting Systems InstallationDirect Venting (Two-pipe System) Vent and Air Intake Pipe Starter Adaptors - PP(s)WARNING(For this ty

Page 45 - Vent Requirements - CPVC

55547 909 - 05Rigid Venting Systems InstallationTable of ContentsDirect Venting (Two-pipe System) (continued)Single Pipe Venting(Room Air Dependent)Re

Page 46

505547 909 - 05Rigid Venting Systems Installation Vent Pipe Starter Adaptors - PP(s) (continued)Fig. 45Legend a 3 in. (76 mm) b 2¾ in. (70 mm) c

Page 47

515547 909 - 05Rigid Venting Systems InstallationDirect Venting (Two-pipe System) Side Wall Vent Termination - Stainless Steel, CPVC or PP(s)IMPORTANT

Page 48

525547 909 - 05Rigid Venting Systems Installation Vent Length RequirementsMaximum vent/air intake pipe length - horizontalIMPORTANTAlways include vent

Page 49 - Flue Air

535547 909 - 05Rigid Venting Systems InstallationDirect Venting (Two-pipe System) Vent Length Requirements (continued)Fig. 51 Vitodens 200-W WB2B 45,

Page 50 - Flue Air

545547 909 - 05Rigid Venting Systems Installation Vent Length Requirements (continued)Maximum vent/air intake pipe length - vertical (continued)Note:

Page 51

555547 909 - 05Rigid Venting Systems InstallationDirect Venting (Two-pipe System) Vent Length Requirements (continued)Multiple boiler installations (v

Page 52

565547 909 - 05Rigid Venting Systems InstallationAir Flue Vent Length Requirements (continued)Maximum vent/air intake pipe length - horizontal/vertica

Page 53

575547 909 - 05Rigid Venting Systems InstallationDirect Venting (Two-pipe System) Vent Length Requirements (continued)Maximum vent/air intake pipe len

Page 54

585547 909 - 05Rigid Venting Systems Installation Vent Length Requirements (continued)Equivalent vent length calculation example - stainless steel sys

Page 55

595547 909 - 05Rigid Venting Systems InstallationDirect Venting (Two-pipe System) Vent Length Requirements (continued)Equivalent vent length calculati

Page 56 - DB2HA 80, 100, 112

65547 909 - 05Rigid Venting Systems InstallationTable of Contents PageComponent parts of the venting system - stainless steel...

Page 57

605547 909 - 05Rigid Venting Systems Installation Vent Length Requirements (continued)Direct Venting (Two-pipe System)LegendA Support systemB Exhaust

Page 58

615547 909 - 05Rigid Venting Systems InstallationB2HA 19, 28, 35B2HB 19, 26, 35B2TA 19, 35B2TB 19, 35 Component Parts of the PP(s) Venting SystemDirec

Page 59

625547 909 - 05Rigid Venting Systems InstallationB2HA 19, 28, 35B2HB 19, 26, 35B2TA 19, 35B2TB 19, 35 Component Parts of the PP(s) Venting System (con

Page 60

635547 909 - 05Rigid Venting Systems Installation Venting - Single Pipe (Room Air Dependent)This system draws combustion air from the boiler room. Roo

Page 61

645547 909 - 05Rigid Venting Systems Installation Vent Requirements Combustion air supplyThis boiler requires fresh air for safe operation and must be

Page 62

655547 909 - 05Rigid Venting Systems InstallationSingle Pipe Venting (Room Air Dependent) Vent Requirements (continued)Combustion air supply (continue

Page 63

665547 909 - 05Rigid Venting Systems InstallationInstallation steps (outline)Exhaust vent pipe materialUse only the materials listed in table 30 for e

Page 64 - Vent Requirements

675547 909 - 05Rigid Venting Systems InstallationSingle Pipe Venting (Room Air Dependent) General Installation Information (continued)Approved materia

Page 65

685547 909 - 05Rigid Venting Systems Installation General Installation Information (continued)Single Pipe Venting (Room Air Dependent)8...underneath a

Page 66

695547 909 - 05Rigid Venting Systems InstallationSingle Pipe Venting (Room Air Dependent) General Installation Information (continued)Support systemTh

Page 67

75547 909 - 05Rigid Venting Systems Installation Important Regulatory and Installation RequirementsFor installations on the Commonwealth of Massachuse

Page 68

705547 909 - 05Rigid Venting Systems Installation General Installation Information (continued)Additional requirements for stainless steel vent pipe ma

Page 69

715547 909 - 05Rigid Venting Systems InstallationSingle Pipe Venting (Room Air Dependent) General Installation Information (continued)Additional requi

Page 70

725547 909 - 05Rigid Venting Systems Installation General Installation Information (continued)Additional requirements for stainless steel vent pipe ma

Page 71

735547 909 - 05Rigid Venting Systems InstallationSingle Pipe Venting (Room Air Dependent) General Installation Information (continued)Additional requi

Page 72

745547 909 - 05Rigid Venting Systems Installation General Installation Information (continued)Additional requirements for CPVC vent pipe materialUse U

Page 73

755547 909 - 05Rigid Venting Systems InstallationTable 34 Required starter adaptors and mesh screen for CPVC systemPart Boiler Model Size Supplier Qua

Page 74

765547 909 - 05Rigid Venting Systems Installation Requirements for UL/ULC Listed Rigid PP(s) Vent Pipe MaterialWhen replacing parts, use original manu

Page 75

775547 909 - 05Rigid Venting Systems InstallationSingle Pipe Venting (Room Air Dependent)Vent pipe starter adaptors for WB1B 26, 35, B2TA 19, 35, B2TB

Page 76

785547 909 - 05Rigid Venting Systems Installation Side Wall Vent TerminationFor PP(s) systems, all exhaust vent and air intake piping and elbows expos

Page 77

795547 909 - 05Rigid Venting Systems InstallationSingle Pipe Venting (Room Air Dependent) Vent Length RequirementsMaximum vent pipe length - horizonta

Page 78 - Side Wall Vent Termination

85547 909 - 05Rigid Venting Systems Installation Important Regulatory and Installation Requirements (continued)The venting system must be installed by

Page 79

805547 909 - 05Rigid Venting Systems Installation Vent Length Requirements (continued)Maximum vent pipe length - verticalAll PP(s) vent material and a

Page 80

815547 909 - 05Rigid Venting Systems InstallationSingle Pipe Venting (Room Air Dependent) Vent Length Requirements (continued)Standard long sweep elbo

Page 81 - For plastic pipe only

825547 909 - 05Rigid Venting Systems Installation Component Installation GuideGeneral single-pipe vertical venting layoutLegend1 Coaxial vent pipe ada

Page 82

835547 909 - 05Rigid Venting Systems InstallationSingle Pipe Venting (Room Air Dependent) Component Installation Guide (continued)Single-pipe vent sta

Page 83

845547 909 - 05Rigid Venting Systems Installation Component Installation Guide (continued)See table below for the following two conditions. For slope

Page 84

855547 909 - 05Rigid Venting Systems InstallationSingle Pipe Venting (Room Air Dependent) Component Installation Guide (continued)Fig. 89Fig. 90Multi

Page 85

865547 909 - 05Rigid Venting Systems Installation Component Installation Guide (continued)Single-pipe vent termination installationInstall the vent te

Page 86

875547 909 - 05Rigid Venting Systems InstallationSingle Pipe Venting (Room Air Dependent) Component Installation Guide (continued)Equivalent vent leng

Page 87

885547 909 - 05Rigid Venting Systems Installation Installation of Support System - (PPs)The venting system must be securely supported by a support sys

Page 88

895547 909 - 05Rigid Venting Systems Installation Two Pipe Options WB1B 26/35, WB2B 19/26/35, B2TA/B2TB 19/35, B2HA 19/28/35, B2HB 19/26/35 (Direct V

Page 89

95547 909 - 05Rigid Venting Systems InstallationSafety Important Regulatory and Installation Requirements (continued) Table 1. Clearance to combustibl

Page 90

905547 909 - 05Rigid Venting Systems Installation Single Pipe Options WB1B 26/35, WB2B 19/26/35, B2TA/B2TB 19/35, B2HA 19/28/35, B2HB 19/26/35 (Room A

Page 91

915547 909 - 05Rigid Venting Systems InstallationComponentry (System Options) Two Pipe Options WB2B 45/60, B2HA 45/60 (Direct Vent) IMPORTANTFor PP(s)

Page 92

925547 909 - 05Rigid Venting Systems Installation Single Pipe Options WB2B 45/60, B2HA 45/60 (Room Air Dependent) For PP(s) systems, all exhaust vent

Page 93

935547 909 - 05Rigid Venting Systems InstallationComponentry (System Options) Two Pipe Options WB2B 80/105, B2HA 80, 100, 112, 150 (Direct Vent) IMPOR

Page 94

945547 909 - 05Rigid Venting Systems Installation Single Pipe Options WB2B 80/105, B2HA 80, 100, 112, 150 (Room Air Dependent) For PP(s) systems, all

Page 95

955547 909 - 05Rigid Venting Systems InstallationComponentry (System Options) Coaxial Vent System Options (Direct Vent) WB1B 26/35, B2TA 19/35 WB2B 19

Page 96

5547 909 - 05Rigid Venting Systems Installation Technical information subject to change without notice.Printed on environment

Commentaires sur ces manuels

Pas de commentaire