Viessmann VD2A Series Manuel de service

Naviguer en ligne ou télécharger Manuel de service pour Chauffe-eau et chaudières Viessmann VD2A Series. Viessmann VD2A Series Technical data Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
for use by heating contractor
5354 787 - 01 04/2014
Technical Data Manual
VITOROND 200
Oil-/Gas-fired boiler
triple-pass sectional cast iron design with Eutectoplex heat transfer surface
and Therm-Control integrated low temperature protection logic
for operation with modulating water temperatures
Heating input: 490 to 1096 MBH
(144 to 321 kW)
Product may not be exactly as shown
Vitorond 200, VD2A Series
Triple-pass hot water heating boiler
490 to 1096 MBH (144 to 321 kW)
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - VITOROND 200

for use by heating contractor5354 787 - 01 04/2014Technical Data ManualVITOROND 200Oil-/Gas-fired boiler triple-pass sectional cast iron design with

Page 2 - Product Information

Vitorond 200, VD2A Technical Data 5354 787 - 0110Technical DataBoiler Connection Kit (standard equipment) LegendSS Safety supply - connection to pr

Page 3

115354 787 - 01Vitorond 200, VD2A Technical Data Technical DataClearances to CombustiblesThe combustion chamber door is factory assembled to hinge on

Page 4

Vitorond 200, VD2A Technical Data 5354 787 - 0112Technical DataWaterside FlowThe Vitorond 200 boiler is designed for closed loop, forced circulation,

Page 5

135354 787 - 01Vitorond 200, VD2A Technical Data Technical DataBurner CalibrationBurner manufacturerWeishaupt or RielloBurner/Gas train approvalStand

Page 6 - Cross-Section

Vitorond 200, VD2A Technical Data 5354 787 - 0114Technical DataNew Casting Design and Therm-Control FunctionalitySystem return water enters the cast

Page 7

155354 787 - 01Vitorond 200, VD2A Technical Data Technical DataTherm-Control Low-Temperature Protection LogicA specific, matching boiler control is p

Page 8 - Technical Data (continued)

Vitorond 200, VD2A Technical Data 5354 787 - 0116Standard EquipmentNote: Boiler controls and burners are purchased separately. Please see Price List

Page 9

175354 787 - 01Vitorond 200, VD2A Technical Data Boiler ControlBoiler Control AlternativesFor multiple-boiler installations:Vitotronic 100, GC1/GC1B

Page 10 - IMPORTANT

Vitorond 200, VD2A Technical Data 5354 787 - 0118Boiler ControlBoiler Control Alternatives (continued)Custom control panelsFor single-boiler or multi

Page 11 - Clearances to Combustibles

195354 787 - 01Vitorond 200, VD2A Technical Data Single-Boiler System: Vitorond 200, VD2A with Therm-ControlBoiler ControlDHW heatingThe DHW is heate

Page 12 - Waterside Flow

Vitorond 200, VD2A Technical Data 5354 787 - 01Product InformationSafety and Installation RequirementsRefer to the Installation Instructionsapplicabl

Page 13 - Burner Calibration

Vitorond 200, VD2A Technical Data 5354 787 - 0120Single-Boiler System: Vitorond 200, VD2A with Therm-Control (continued)Boiler ControlLegendA Heating

Page 14 - Technical Data

215354 787 - 01Vitorond 200, VD2A Technical Data Boiler ControlMulti-Boiler System: Vitorond 200, VD2A with Therm-ControlFunction descriptionThe Ther

Page 15

Vitorond 200, VD2A Technical Data 5354 787 - 0122Multi-Boiler System, Vitorond 200, VD2A with Therm-Control (continued)Boiler ControlsÖM3 Heating

Page 16 - Standard Equipment

235354 787 - 01Vitorond 200, VD2A Technical Data System DesignBurner calibrationWith 2-stage and fully modulating burners, ensure that the chimney is

Page 17 - Boiler Control Alternatives

Vitorond 200, VD2A Technical Data 5354 787 - 0124System DesignSystem Design Considerations (continued)Barometric draft regulatorBarometric draft regu

Page 18 - Boiler Control

255354 787 - 01Vitorond 200, VD2A Technical Data System DesignSystem Design Considerations (continued)Combustion air supplyThe boiler must not be loc

Page 19

Vitorond 200, VD2A Technical Data 5354 787 - 0126System Design Considerations (continued)System DesignAnti-vibration measuresAnti-vibration supports

Page 20

275354 787 - 01Vitorond 200, VD2A Technical Data Weishaupt Burners - LinkagelessBoiler model VD2A- 125 160 195 230 270No. 2 oil-fired2-stageModel WL2

Page 21

Technical information subject to change without notice. Printed on environmentally friendly (recycled and recyclable) paper.5354

Page 22

PageTable of Contents5354 787 - 01Vitorond 200, VD2A Technical Data Product InformationTechnical DataSafety and Installation Requirements ...

Page 23 - System Design Considerations

4 PageTable of Contents5354 787 - 01Vitorond 200, VD2A Technical DataStandard Equipment ...16Standard eq

Page 24

5 PageTable of Contents5354 787 - 01Vitorond 200, VD2A Technical Data System Design Burner System Design Considerations ...

Page 25

Vitorond 200, VD2A Technical Data 5354 787 - 016Product InformationCross-SectionViessmann North America offers the side-mounted control option only.L

Page 26 - System Design

75354 787 - 01Vitorond 200, VD2A Technical Data Technical DataBoiler ModelVD2A-125160195230270Input (oil)*1MBH (kW)490 (144)628 (184)765 (224)902 (26

Page 27 - Burner Alternatives

Vitorond 200, VD2A Technical Data 5354 787 - 018Technical DataTechnical Data (continued)Boiler ModelVD2A-125160195230270Weight Front section(with com

Page 28 - 5354 787 - 01

95354 787 - 01Vitorond 200, VD2A Technical Data Technical DataTechnical Data (continued)Burner InstallationThe burner must be fitted to the burner pl

Commentaires sur ces manuels

Pas de commentaire