Technical Data Manual
VITODENS
r
200-W
5683 718 - 04 04/2015
Model Nos. and pricing: see Price List
Gas-fired wall-mounted condensing boiler
104 to 530 MBH (30 to 155 kW)
Multi-boiler installation 104 to 4240 MBH
For Natural Gas and Liquid Propane Gas
Product may not be exactly as shown
Vitodens 200-W
Series B2HA Series, Models 100, 112 and 150
Gas-Fired Wall-Mounted Condensing Boiler
with modulating MatriX cylinder burner
for room air independent operation
(using a direct vent system or room air
dependent operation).
H
Vue de la page 0
1 2 3 4 5 6 ... 51 52

Résumé du contenu

Page 1 - VITODENS

Technical Data ManualVITODENSr 200-W5683 718 - 04 04/2015Model Nos. and pricing: see Price ListGas-fired wall-mounted condensing boiler104 to 530 MBH

Page 2 - Vitodens 200-W

5683 718 - 0410Vitodens 200-W B2HA 100 to 150 Technical DataSystem Flow RatesBoiler B2HA 112 maximum flow rate; 38 GPM (8600 L/h)Boiler B2HA 100 maxim

Page 3 - Cross-Section

115683 718 - 04Pump InformationHeating Circuit / Boiler PumpsViessmann offers a variety of Grundfos heating circuit / boiler pumps which meet typical

Page 4 - Technical Data

5683 718 - 0412Vitodens 200-W B2HA 100 to 150 Technical DataLow-Loss Header ApplicationLow-Loss Header InformationNote: for multiple boiler applicatio

Page 5 - Technical Data (continued)

Vitodens 200-W B2HA 100 to 150 Technical Data135683 718 - 04Low-Loss Header InformationLow-Loss Header Application (continued)BoilerModelNo. ofBoilers

Page 6 - Model B2HA 100

Vitodens 200-W B2HA 100 to 150 Technical Data5683 718 - 0414Low-Loss Header Application (continued)Low-Loss Header InformationBoilerModelNo. ofBoilers

Page 7

155683 718 - 04DHW ProductionDomestic Hot Water ProductionVitodens 200-W boilers can be used in conjunction with the stand-alone DHW storage tanks off

Page 8 - Minimum Clearances

5683 718 - 0416DHW Recirculation/ Boiler MountingDomestic Hot Water RecirculationDHW recirculation lines increase the level of comfort and convenience

Page 9 - Waterside Flow

175683 718 - 04Boiler MountingModel B2HA 100 Wall Mount1. Remove the external accessories connection box cover.2. Loosen the screws at the bottom

Page 10 - Typical System Flow Rates

Vitodens 200-W B2HA 100 to 150 Technical Data5683 718 - 0418Boiler Stand for B2HA 112 and 150The boiler stand is used for free-standing installation o

Page 11 - IMPORTANT

Vitodens 200-W B2HA 100 to 150 Technical Data195683 718 - 04Boiler MountingModel B2HA 100 Stand MountThe Vitodens 200-W, model B2HA does not come with

Page 12 - Low-Loss Header Application

5683 718 - 042Vitodens 200-W B2HA 100 to 150 Technical DataProduct InformationVitodens 200-W2The benefits at a glance: Best value in its class with n

Page 13

5683 718 - 0420Boiler MountingModels B2HA 112, 150The Vitodens 200-W, model B2HA does not come with a mounting template. The wall location for the fra

Page 14 - Low-Loss Header Information

215683 718 - 04Condensate Connection/Neutralization UnitCondensate ConnectionInstall the condensate drain pipe with a suitable gradient. Discharge con

Page 15 - Domestic Hot Water Production

5683 718 - 0422Venting Options/Electrical Connection/ControlVenting OptionsVent Connection, models B2HA 100Vent Connection, models B2HA 112, 150For de

Page 16 - 5683 718 - 04

235683 718 - 04Boiler ControlOn-Board Vitotronic 200, HO1B ControlModular structureThe control unit is integrated into the boiler. The control unit co

Page 17 - Model B2HA 100 Wall Mount

5683 718 - 0424Boiler ControlDesign and FunctionFunctions Weather-compensated control of the boiler water and/or flow temperature Control of on

Page 18 - Boiler Stand for B2HA 100

255683 718 - 04Boiler ControlDesign and Function (continued)Heating Curve Adjustment (slope and shift)The control unit regulates the boiler water temp

Page 19 - Model B2HA 100 Stand Mount

5683 718 - 0426Boiler Temperature Sensor The boiler temperature sensor is connected at the control unit for weather-responsive operation and is built

Page 20 - Models B2HA 112, 150

275683 718 - 04Control AccessoriesVitotronic Control AccessoriesMixing Valve Extension ModuleRated voltage: 120 VACRated frequency: 60 HzRated cu

Page 21 - Condensate Connection

5683 718 - 0428Control AccessoriesVitotronic Control Accessories (continued)KM BUS Expansion ModuleTo connect 2 to 9 devices (mixing valve actuator, V

Page 22 - Electrical Connections

295683 718 - 04Control AccessoriesVitotronic Control Accessories (continued)Vitotrol 300AOne Vitotrol 300A can be used for every heating circuit in a

Page 23 - Boiler Control

35683 718 - 04Vitodens 200-W B2HA 100 to 150 Technical DataProduct Information3Cross-SectionProducts may not be exactly as shownA Inox-Radial heat ex

Page 24 - Design and Function

5683 718 - 0430AccessoriesAccessories for Vitodens 200-WNeutralization Unit for Single-Boiler Applicationswith neutralizing granulate for models B2HA

Page 25

315683 718 - 04AccessoriesAccessories for Vitodens 200-WLow-Loss Header (continued)Use only a Viessmann supplied temperature sensor. Do not use any ot

Page 26

5683 718 - 0432Standard Equipment/Management SystemStandard EquipmentCombustion Management SystemThe Vitodens 200-W gas-fired condensing boiler with I

Page 27 - Control Accessories

335683 718 - 04InstallationInstallation ExamplesPlease note that in the following piping layout examples, all pumps are field supplied.IMPORTANT IMPOR

Page 28

5683 718 - 04Installation ExamplesSystem Layout 1Vitodens 200-W B2HA 100 to 150 Technical DataVitodens 200-W, B2HA with a direct-connected heating cir

Page 29

5683 718 - 0435Vitodens 200-W B2HA 100 to 150 Technical DataInstallation ExamplesSystem Layout 2Vitodens 200-W, B2HA with one heating circuit and low-

Page 30 - Accessories

5683 718 - 04Vitodens 200-W B2HA 100 to 150 Technical DataInstallation ExamplesSystem Layout 336Vitodens 200-W, B2HA with... - DHW storage tank -

Page 31

5683 718 - 04Vitodens 200-W B2HA 100 to 150 Technical Data37Installation ExamplesSystem Layout 4Vitodens 200-W, B2HA with... - DHW storage tank - on

Page 32 - Combustion Management System

Vitodens 200-W B2HA 100 to 150 Technical Data5683 718 - 04Installation ExamplesSystem Layout 5Vitodens 200-W, B2HA with... - DHW storage tank - one

Page 33 - Hydraulic Connection

5683 718 - 04Installation ExamplesSystem Layout 6Vitodens 200-W B2HA 100 to 150 Technical DataVitodens 200-W, B2HA with... - DHW storage tank - one

Page 34 - System Layout 1

5683 718 - 044Vitodens 200-W B2HA 100 to 150 Technical DataTechnical DataTechnical Data4*A For high altitude installations 5,000 - 10,000 ft. (1500

Page 35 - System Layout 2

5683 718 - 04Vitodens 200-W B2HA 100 to 150 Technical DataInstallation Examples40System Layout 7Vitodens 200-W, B2HA with... - direct-connected heati

Page 36 - System Layout 3

415683 718 - 04Vitodens 200-W B2HA 100 to 150 Technical DataInstallation ExamplesSystem Layout 8Vitodens 200-W, B2HA with... - DHW storage tank - lo

Page 37 - System Layout 4

5683 718 - 04Vitodens 200-W B2HA 100 to 150 Technical DataInstallation ExamplesSystem Layout 942Multiple (up to eight) Vitodens 200-W, models B2HA 100

Page 38 - System Layout 5

435683 718 - 04Vitodens 200-W B2HA 100 to 150 Technical DataInstallation ExamplesAlternative DHW ConnectionThe following piping diagram reflects an al

Page 39 - System Layout 6

Vitodens 200-W B2HA 100 to 150 Technical DataWiring DiagramOverview of Electrical Connections, Models B2HA 1005683 718 - 0444If any of the original wi

Page 40 - System Layout 7

Vitodens 200-W B2HA 100 to 150 Technical Data45Wiring DiagramOverview of Electrical Connections, Models B2HA 100 (continued)A Boiler ControlB Extern

Page 41 - System Layout 8

5683 718 - 0446Wiring DiagramOverview of Electrical Connections, Models B2HA 112 and 150Vitodens 200-W B2HA 100 to 150 Technical DataIf any of the ori

Page 42 - System Layout 9

475683 718 - 04Wiring DiagramOverview of Electrical Connections, Models B2HA 112 and 150 (continued)Vitodens 200-W B2HA 100 to 150 Technical DataA Bo

Page 43 - Alternative DHW Connection

5683 718 - 04Vitodens 200-W B2HA 100 to 150 Technical DataSystem DesignSystem Design ConsiderationsIN THE COMMONWEALTH OF MASSACHUSETTS... - this p

Page 44 - Wiring Diagram

495683 718 - 04Vitodens 200-W B2HA 100 to 150 Technical DataSystem DesignSystem Design Considerations (continued)System layout The max. boiler water

Page 45

55683 718 - 04Vitodens 200-W B2HA 100 to 150 Technical DataTechnical Data5Technical Data (continued)*A For high altitude installations 5,000 - 10,00

Page 46

Vitodens 200-W B2HA 100 to 150 Technical Data5683 718 - 0450

Page 47

Vitodens 200-W B2HA 100 to 150 Technical Data515683 718 - 04

Page 48 - System Design Considerations

Technical information subject to change without notice. Printed on environmentally friendly (recycled and recyclable) paper.Vitod

Page 49 - System Design

5683 718 - 046Vitodens 200-W B2HA 100 to 150 Technical DataDimensional InformationModel B2HA 100Legend A Boiler SupplyB Gas Connection, 1” NPTFC

Page 50

75683 718 - 04Vitodens 200-W B2HA 100 to 150 Technical DataDimensional InformationModels B2HA 112, 150Legend A Boiler SupplyB Gas Connection, 1” N

Page 51

5683 718 - 048Vitodens 200-W B2HA 100 to 150 Technical DataMinimum ClearancesRecommended Minimum Service ClearancesMinimum Clearances to CombustiblesA

Page 52

95683 718 - 04Supply head pressure (water)Flow rateVitodens 200-W B2HA 100 to 150 Technical DataWaterside FlowWaterside Flow (primary circuit)Supply h