Viessmann VITODENS 200 WB2 Series Guide de dépannage

Naviguer en ligne ou télécharger Guide de dépannage pour Chauffe-eau et chaudières Viessmann VITODENS 200 WB2 Series. Viessmann VITODENS 200 WB2 Series Troubleshooting guide [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
5351 934
v1.0 10/2007 Page 1 of 16
VITODENS 200
Troubleshooting Guide
This guide is for internal use only and is NOT a substitute for the technical support literature supplied with the Vitodens 200 boiler and the
accessories. Use in conjunction with Vitodens 200 Quick Start-up Guide and Start-up/Service Instructions.
Before getting started, remember…
All Vitodens 200 boilers have passed rigorous functionality testing and come factory-tested for proper
operation.
Approximately 85% of all field issues are associated with items external to the boiler, such as:
Air in the water system (at start-up, air must be purged completely for at least 1 hour)
Wrong programming (coding) match to connected system
Air in the gas line (specifically for LP)
Wrong pump designation, coding or assignment
Power supply issues (reversed polarity, improper grounding, Ground Fault Interrupted supply, or
unstable power supply).
Off-grid power supply such as generators, battery back-up.
Only a few measurements without burner calibrations need to be performed on the boiler. The following are
items that do require measurements:
Inlet gas pressure (static and running)
Combustion flue gases and air intake (for direct vent systems)
Power supply
Certain fuses
When changing the coding addresses the boiler must be restarted (power ON/OFF) at least once for the
changes to take effect. The control needs between 2 and 60 seconds to process and transfer data.
From our own experience, we have replaced the following components on the boilers in the following order:
VR20 circuit board
LGM burner control unit
Fan assemblies
Complete burner assembly (some due to damage of the inlet air damper)
When troubleshooting the Vitodens 200 avoid jumping to the premature conclusion that parts such as
VR20, LGM etc., or the boiler are defective. It is important to avoid this assumption.
Troubleshooting Steps When the Customer Calls
Step 1 Collect pertinent information. Please use the Vitodens Diagnostics sheets if possible. A copy is attached
at the end of this document for convenience.
Record the boiler model number, gas type, venting type, system layout connected to boiler, accessory and
equipment used (Low-Loss Header (LLH), mixing valves, etc).
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - VITODENS 200

5351 934 v1.0 10/2007 Page 1 of 16 VITODENS 200 Troubleshooting Guide This guide is for internal use only and

Page 2 - Who to contact…

5351 934 v1.0 10/2007 Page 10 of 16 Item Field Service Calls Suggested Solution 38 Snow melt and pool heat

Page 3 - Service Call Overview

5351 934 v1.0 10/2007 Page 11 of 16 Item Field Service Calls Suggested Solution 43 Replacement parts  Com

Page 4

VITODENS 200 CAUTION The installation, adjustment, service, and maintenance of this product must be

Page 5

The following information must be made available to us to assist in the diagnosis. System Layout Usi

Page 6 - 5351 934

Address Recorded Value 000 003 005 007 008 010 011 013 Address Recorded Value 042 044 045 046 099 0A0 0A2 0A

Page 7

System Sketch

Page 8

Printed on environmentally friendly (recycled and recyclable) paper. 5351 934 v1.5 Technical information subject to change without notic

Page 9

5351 934 v1.0 10/2007 Page 2 of 16 Step 2 Follow start-up procedures For new installations, the first tool is

Page 10

5351 934 v1.0 10/2007 Page 3 of 16 Service Call Overview Important: Read the information on pages 1 and 2 befo

Page 11

5351 934 v1.0 10/2007 Page 4 of 16 Field Service Calls Suggested Solution 5 Boiler short cycling on a shor

Page 12 - Diagnostic Sheets

5351 934 v1.0 10/2007 Page 5 of 16 Item Field Service Calls Suggested Solution 13 Electrical Breakers Tripp

Page 13

5351 934 v1.0 10/2007 Page 6 of 16 Troubleshooting Fault Code 06

Page 14

5351 934 v1.0 10/2007 Page 7 of 16 Field Service Calls Suggested Solution 19 Problems with multiple Vitode

Page 15 - System Sketch

5351 934 v1.0 10/2007 Page 8 of 16 Item Field Service Calls Suggested Solution 25 Fault 14  Gas line nee

Page 16

5351 934 v1.0 10/2007 Page 9 of 16 Item Field Service Calls Suggested Solution 31 Dashes displayed instead

Commentaires sur ces manuels

Pas de commentaire