Installation Instructions
Flexible Pipe Venting System
5547 910 - 06 03/2015
for use by heating contractor
for Vitodens 100-W WB1B Series,
Vitodens 200-W WB2B Series,
Vitodens 200-W B2HA/B2HB Series and
Vitodens 222-F B2TA/B2TB Series
All boilers listed come with a preinstalled
coaxial vent pipe adaptor.
Please file in service binder
Read and save these instructions
for future reference.
Product may not be exactly as shown
IMPORTANT
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - Installation Instructions

Installation InstructionsFlexible Pipe Venting System5547 910 - 06 03/2015for use by heating contractorfor Vitodens 100-W WB1B Series, Vitodens 200-

Page 2

10 5547 910 - 06Flexible Venting Installation Exhaust Vent RequirementsGeneral InformationThe Vitodens 100-W, 200-W and 222-F boilers must be located

Page 3 - Table of Contents

115547 910 - 06Flexible Venting InstallationGeneral Information General Installation InformationExhaust vent installation stepsThe flexible pipes, rig

Page 4

12 5547 910 - 06Flexible Venting InstallationGeneral InformationExhaust vent installation steps (continued) Once the bottom of the flex pipe and ad

Page 5

135547 910 - 06Flexible Venting InstallationDirect Venting (Two-pipe System) Combustion Air SupplyThe Vitodens boiler is suitable for vertical venting

Page 6

14 5547 910 - 06Flexible Venting Installation Venting Options (Two-pipe System)Boiler models; Vitodens 100-W WB1B 26, 35, Vitodens 200-W WB2B 19, 26,

Page 7

155547 910 - 06Flexible Venting InstallationDirect Venting (Two-pipe System) Starter AdaptorVent pipe starter adaptors for WB1B 26, 35,WB2B 19, 26, 35

Page 8

16 5547 910 - 06Flexible Venting Installation Parallel AdaptorTable 4. Parallel adaptor for two-pipe systemSupplier Boiler Model Ø in. (mm) QuantityV

Page 9

175547 910 - 06Flexible Venting InstallationDirect Venting (Two-pipe System) Vent Requirements - Flexible Vent System / Connector PipesAdditional requ

Page 10 - Exhaust Vent Requirements

18 5547 910 - 06Flexible Venting Installation Side Wall Air Intake TerminationThe air intake system must terminate so that proper clearances are main

Page 11 - General Information

195547 910 - 06Flexible Venting InstallationDirect Venting (Two-pipe System) Vent Length RequirementsMaximum exhaust vent pipe length vertical and air

Page 12 - IMPORTANT

2 5547 910 - 06Flexible Venting Installation About these Installation InstructionsTake note of all symbols and notations intended to draw attention t

Page 13 - Combustion Air Supply

20 5547 910 - 06Flexible Venting Installation Vent Length Requirements (continued)Maximum exhaust vent pipe length vertical and air intake pipe lengt

Page 14

215547 910 - 06Flexible Venting InstallationDirect Venting (Two-pipe System) Vent Length Requirements (continued)Standard long sweep elbows (for CPVC

Page 15 - Starter Adaptor

22 5547 910 - 06Flexible Venting InstallationIf boiler is installed in a confined space (a space with a volume of less than 50 cubic feet per 1000 Bt

Page 16 - Parallel Adaptor

235547 910 - 06Flexible Venting InstallationSingle Pipe Venting (Room Air Dependent) Combustion Air Supply (continued)* Typically when the boiler is

Page 17 - Flexible Venting Installation

24 5547 910 - 06Flexible Venting Installation Venting Options (Room Air Dependent)Fig. 18 Single Pipe Venting (Room Air Dependent)This system draws

Page 18

255547 910 - 06Flexible Venting Installation Vent Length RequirementsMaximum vent pipe length - verticalLegendA Combustion air intake (left, right or

Page 19 - Vent Length Requirements

26 5547 910 - 06Flexible Venting InstallationSingle Pipe Venting (Room Air Dependent) Component Installation GuideSingle pipe vent pipe starter adapt

Page 20

275547 910 - 06Flexible Venting Installation General Component Parts of the Venting System Fig. 25ComponentryLegendA Combustion air intakeB Flue gas

Page 21

Flexible Venting Installation Instructions5547 910 - 06 Technical information subject to change without notice.Printed on en

Page 22

35547 910 - 06Flexible Venting InstallationTable of ContentsSafetyGeneral InformationDirect Venting(Two-pipe System)Single Pipe Venting(Room Air Depen

Page 23 - CAUTION*

4 5547 910 - 06Flexible Venting Installation Safety, Installation and Warranty RequirementsPlease ensure that these instructions are read and underst

Page 24

55547 910 - 06Flexible Venting InstallationSafety Important Regulatory and Installation RequirementsFor installations on the Commonwealth of Massachus

Page 25 - Adaptors

6 5547 910 - 06Flexible Venting Installation Important Regulatory and Installation Requirements (continued)SafetyWhen replacing parts, use original V

Page 26 - Component Installation Guide

75547 910 - 06Flexible Venting InstallationSafety Important Regulatory and Installation Requirements (continued)1..directly above a paved sidewalk or

Page 27 - Componentry

8 5547 910 - 06Flexible Venting Installation Important Regulatory and Installation Requirements (continued)SafetyTable 1. Clearance to combustiblesTo

Page 28

95547 910 - 06Flexible Venting InstallationSafety Important Regulatory and Installation Requirements (continued)Part Material Certified to Standards A