Viessmann VITODENS 222-W Manuel de service

Naviguer en ligne ou télécharger Manuel de service pour Chauffe-eau et chaudières Viessmann VITODENS 222-W. Viessmann VITODENS 222-W Technical data Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Technical Data Manual
VITODENS
r
222-F
5683 719 - 05 03/2015
Model Nos. and pricing: see Price List
For Natural Gas and Liquid Propane Gas
Gas-fired floor-mounted condensing DHW combi-boiler
12 to 125 MBH (3.5 to 37 kW)
Product may not be exactly as shown
Vitodens 222-F
B2TA Series 19 and 35
Gas-fired floor-mounted condensing DHW
combi-boiler with modulating MatriX
cylinder burner and DHW stainless steel
tank. For room air independent operation
or room air dependent operation.
H
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - VITODENS

Technical Data ManualVITODENSr 222-F5683 719 - 05 03/2015Model Nos. and pricing: see Price ListFor Natural Gas and Liquid Propane Gas Gas-fired floo

Page 2 - Vitodens 222-F

Vitodens 222-F, B2TA 19 and 35 Technical Data5683 719 - 0510Low-Loss Header InformationHeating Circuit PumpsPump Model Grundfos UPS15-

Page 3 - Cross-Section

Vitodens 222-F, B2TA 19 and 35 Technical Data115683 719 - 05DHW ProductionDomestic Hot Water ProductionA diaphragm expansion tank is integrated into t

Page 4 - Technical Data

Vitodens 222-F, B2TA 19 and 35 Technical Data5683 719 - 0512Boiler ControlOn-Board Vitotronic 200, HO1B ControlModular structureThe control unit is in

Page 5

Vitodens 222-F, B2TA 19 and 35 Technical Data135683 719 - 05Frost protection The frost protection function will be started when the outside tempe

Page 6 - Models 222-F, B2TA 19 and 35

Vitodens 222-F, B2TA 19 and 35 Technical Data5683 719 - 0514Boiler ControlDesign and Functions (continued)Heating Curve Adjustment (slope and shift)Th

Page 7 - Minimum Clearances

Vitodens 222-F, B2TA 19 and 35 Technical Data155683 719 - 05Design and Functions (continued)Boiler Temperature Sensor The boiler temperature sensor is

Page 8 - Waterside Flow

Vitodens 222-F, B2TA 19 and 35 Technical Data5683 719 - 0516AccessoriesVitotronic Control AccessoriesMixing Valve Actuator KitThe mixing valve actuato

Page 9 - Low-Loss Header Application

Vitodens 222-F, B2TA 19 and 35 Technical Data175683 719 - 05Mixing Valve Extension ModuleRated voltage: 120 VACRated frequency: 60 HzRated curren

Page 10 - Heating Circuit Pumps

Vitodens 222-F, B2TA 19 and 35 Technical Data5683 719 - 0518Vitotrol 300AOne Vitotrol 300A can be used for every heating circuit in a heating system.

Page 11 - IMPORTANT

Vitodens 222-F, B2TA 19 and 35 Technical Data195683 719 - 05AccessoriesAccessories for Vitodens 222-FLow-Loss HeaderWhen used in conjunction with the

Page 12 - Boiler Control

Vitodens 222-F, B2TA 19 and 35 Technical Data5683 719 - 052Product InformationVitodens 222-F2Delivered conditionGas condensing boiler with Inox-Radial

Page 13 - Design and Function

Vitodens 222-F, B2TA 19 and 35 Technical Data5683 719 - 0520AccessoriesAccessories for Vitodens 222-FLow-Loss Header (continued)When installing a low-

Page 14

Vitodens 222-F, B2TA 19 and 35 Technical Data215683 719 - 05AccessoriesAccessories for Vitodens 222-FParts for Top Connection0302 Connecting pipe, DHW

Page 15 - Accessories

Vitodens 222-F, B2TA 19 and 35 Technical Data5683 719 - 0522Standard Equipment/Management SystemStandard EquipmentCombustion Management SystemThe Vito

Page 16

Vitodens 222-F, B2TA 19 and 35 Technical Data235683 719 - 05InstallationInstallation ExamplesPlease note that in the following piping layout examples

Page 17

Vitodens 222-F, B2TA 19 and 35 Technical Data5683 719 - 05Installation ExamplesSystem Layout 1Vitodens 222-F, B2TA with a direct-connected heating cir

Page 18

Vitodens 222-F, B2TA 19 and 35 Technical Data255683 719 - 05Installation ExamplesSystem Layout 2Vitodens 222-F, B2TA with one heating circuit, low-los

Page 19

Vitodens 222-F, B2TA 19 and 35 Technical Data5683 719 - 05Installation ExamplesSystem Layout 326Vitodens 222-F, B2TA with... - Integrated DHW produc

Page 20

Vitodens 222-F, B2TA 19 and 35 Technical Data275683 719 - 05System Layout 4Vitodens 222-F, B2TA with... - Integrated DHW production - one direct-con

Page 21

Vitodens 222-F, B2TA 19 and 35 Technical Data5683 719 - 05Installation ExamplesSystem Layout 528Vitodens 222-F, B2TA with... - Integrated DHW product

Page 22 - Combustion Management System

Vitodens 222-F, B2TA 19 and 35 Technical Data295683 719 - 05Installation ExamplesSystem Layout 6Vitodens 222-F, B2TA with... - Integrated DHW product

Page 23 - Hydraulic Connection

Vitodens 222-F, B2TA 19 and 35 Technical Data35683 719 - 05Product Information3Cross-SectionProduct may not be exactly as shownThe flue gas temperatur

Page 24 - System Layout 1

Vitodens 222-F, B2TA 19 and 35 Technical Data5683 719 - 05Installation ExamplesSystem Layout 730Vitodens 222-F, B2TA with... - one direct-connected h

Page 25 - System Layout 2

Vitodens 222-F, B2TA 19 and 35 Technical Data315683 719 - 05Installation ExamplesAlternative ConnectionThe following piping diagram reflects the conne

Page 26 - System Layout 3

Vitodens 222-F, B2TA 19 and 35 Technical Data5683 719 - 05Wiring DiagramOverview of Electrical Connections, Models B2TA 19 and 3532WARNINGDISCONNECT P

Page 27 - System Layout 4

Vitodens 222-F, B2TA 19 and 35 Technical Data335683 719 - 05Overview of Electrical Connections, Models B2TA 19 and 35 (continued)Wiring DiagramA Boil

Page 28 - System Layout 5

Vitodens 222-F, B2TA 19 and 35 Technical Data5683 719 - 0534System DesignSystem Design ConsiderationsIN THE COMMONWEALTH OF MASSACHUSETTS... - this

Page 29 - System Layout 6

Vitodens 222-F, B2TA 19 and 35 Technical Data355683 719 - 05System DesignSystem Design Considerations (continued)Oxygen diffusion barrier underfloor t

Page 30 - System Layout 7

Vitodens 222-F, B2TA 19 to 80 Technical Data5683 719 - 05 Technical information subject to change without notice. Printed on envir

Page 31 - Alternative Connection

Vitodens 222-F, B2TA 19 and 35 Technical Data5683 719 - 054Technical DataTechnical Data4Boiler Model No. 222-F B2TA 19 35Natural Gas / Liquid Propane

Page 32 - Wiring Diagram

Vitodens 222-F, B2TA 19 and 35 Technical Data55683 719 - 05Technical Data5Technical DataBoiler Model No. 222-F B2TA 19 35DimensionsOverall depthOveral

Page 33

Vitodens 222-F, B2TA 19 and 35 Technical Data5683 719 - 056Dimensional InformationModels 222-F, B2TA 19 and 356Note: The dimensional drawing shows exa

Page 34 - System Design Considerations

Vitodens 222-F, B2TA 19 and 35 Technical Data75683 719 - 05Minimum Clearances7Recommended Minimum Service ClearancesMinimum Clearances to Combustibles

Page 35

Vitodens 222-F, B2TA 19 and 35 Technical Data5683 719 - 058Waterside FlowWaterside Flow (primary circuit)Supply head pressure (water)Flow rateThe Vito

Page 36 - 5683 719 - 05

Vitodens 222-F, B2TA 19 and 35 Technical Data95683 719 - 05Pump InformationHeating CircuitViessmann offers a variety of Grundfos heating circuit/boile