Résumé du contenu

Page 1 - Service Instructions

Please file in Service Binder5583 571 - 01 01/2014VITORONDr 100Vitorond 100, VR1 SeriesOil-Fired BoilerHeating input 91 to 140 MBH

Page 2

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0110 Mechanical RoomGeneral InformationWhenever possible install boiler near an outsid

Page 3

115583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Combustion Air Supply (continued)CodesProvisions for combustion and ventilation ai

Page 4 - Table of Contents

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0112Set-upProduct DeliveryCAUTIONDo not lift or position boiler alone.Do not lift by o

Page 5 - Additional Information

135583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Set-upMinimum Clearances to CombustiblesLegendA BoilerB BurnerFor typical instal

Page 6

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0114Boiler Set-up and LocationCAUTIONBoiler must be installed in such a way that oil i

Page 7

155583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Connections Venting ConnectionVitorond 100The vent system must comply with all app

Page 8 - About these Instructions

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0116Venting Connection (continued)ConnectionsLegendA Vitorond boiler with burnerB Ou

Page 9 - Product Information

175583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Water Side Connections (with Hydrostat 3250-Plus Control) LegendA Boiler water sup

Page 10 - Combustion Air Supply

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0118ConnectionsSafety Connections (with Hydrostat 3250-Plus Control)Pressure relief va

Page 11 - General Information

195583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service ConnectionsSafety Connections (with Hydrostat 3250-Plus Control) (continued)1. T

Page 12 - Unpacking Instructions

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 012 Important Safety, Installation, Regulatory and Warranty RequirementsSafetyPlease e

Page 13 - 5583 571 - 01

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0120Connections Water Side Connections (Vitotronic Control)We recommend the installati

Page 14 - Combustion Chamber Insert

215583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service ConnectionsSafety Connections (Vitotronic Control)1. Install bushing/return water

Page 15 - Venting Connection

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0122Connections Safety Connections (Vitotronic Control) (continued)1. To avoid probl

Page 16 - Connections

235583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Perform pressure test on boilerThe boiler must be leak tested before being placed

Page 17

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0124FuelThis boiler is for use with the Beckett #2 fuel oil burner supplied by Viessma

Page 18

255583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Beckett Burner Set-upBurner Mounting1. Remove burner from carton. The mounting f

Page 19

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0126Beckett Burner Set-upOil Piping ConnectionWARNINGDo not use Teflon tape as an oil

Page 20

275583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Beckett Burner Set-upElectrical Connections (with Hydrostat 3250-Plus control)Inst

Page 21

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0128Beckett Burner Set-upElectrical Connections (with Hydrostat 3250-Plus control) (co

Page 22

295583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Installations must follow these codes and requirements:- National Electrical Code

Page 23 - Pressure Testing

35583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Safety Important Safety, Installation, Regulatory and Warranty Requirements (contin

Page 24 - Burner Information

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0130Installations must follow these codesand requirements:- National Electrical Code,

Page 25 - Burner Mounting

315583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Beckett Burner Set-upElectrical Connections (with Vitotronic control) (continued)I

Page 26 - Oil Piping Connection

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0132Beckett Burner Set-upIMPORTANTWARNINGDo not kink capillaries. Proper operation of

Page 27

335583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Installation of Vitotronic Control (continued)1. To avoid problems with removing

Page 28 - Beckett Burner Set-up

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0134Beckett Burner Set-upElectrical Connections (with GeniSys primary control)IMPORTAN

Page 29

355583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Burner InstallationRiello Burner Set-upBurner InformationIMPORTANTRefer to the Ins

Page 30

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0136Riello Burner Set-upBurner MountingRefer to the Instructions suppliedwith Riello b

Page 31

375583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service IMPORTANTRefer to the Instructions suppliedwith Riello burnerWARNINGDo not use Tef

Page 32

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0138Riello Burner Set-upElectrical Connections (with Hydrostat 3250-Plus control)WARNI

Page 33 - Boiler Coding Card

395583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Installations must follow these codes and requirements:- National Electrical Code

Page 34

4 PageTable of Contents5583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service SafetyGeneral InformationSet-upConnectionsBecket Burner Set-

Page 35

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0140Electrical Connections (with Vitotronic control)Riello Burner Set-upWARNINGElectri

Page 36

415583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Electrical Connections (with Vitotronic control) (continued)Installations must fol

Page 37

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0142Riello Burner Set-upWARNINGElectric shock hazard. Can cause severe personal injury

Page 38 - Riello Burner Set-up

435583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service IMPORTANTWARNINGDo not kink capillaries. Proper operation of sensors is not possib

Page 39

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0144Installation of Vitotronic Control1. To avoid problems with removing the top pan

Page 40

455583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Initial Start-upWARNINGVerify completeness of all discussion points on the followi

Page 41

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0146WARNINGDO NOT USE GASOLINE, CRANKCASE DRAININGS OR ANY OIL CONTAINING GASOLINE.Ref

Page 42

475583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Start-upBeckett Burner CalibrationBoiler Model No. VR1-22 VR1-27 VR1-33Burner mode

Page 43

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0148Start-upRiello Burner CalibrationIMPORTANTBoiler Model No. VR1-22 VR1-27 VR1-33Bur

Page 44

495583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Start-upBarometric Draft RegulatorWhen a barometric draft regulator is used, adjus

Page 45 - Initial Start-up

Table of Contents5 Page5583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Start-upConnectionsServiceAdditional InformationInitial Sta

Page 46 - Start-up

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0150 Installation Examples - HydrostatBoiler in a heating/cooling applicationCooling s

Page 47 - Beckett Burner Calibration

515583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Connections Installation Examples - VitotronicWithout mixing valvee.g. with Vitotr

Page 48 - Riello Burner Calibration

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0152 Installation Examples - Vitotronic (continued)LegendA Heating circuitB Spring-loa

Page 49 - Waterside Flow

535583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service ConnectionsWith one low-temperature circuit with 4-way mixing valve, one high temp

Page 50

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0154WARNINGEnsure that warning concerning fiberglass wool and ceramic fiber materials

Page 51

555583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Close combustion chamber door1. Reinsert flue gas turbulators D.2. Reinstall c

Page 52

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0156 Service Procedure (continued)Check heating system and domestic hot water connecti

Page 53

575583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Service Service Procedure (continued)Calibrate the burnerNote: For burner technica

Page 54

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0158Model No. Serial No.VR1-22 Boiler 7249048VR1-27 Boiler 7249049VR1-33 B

Page 55

595583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Additional Information Parts List (continued)Parts001 5-Point sensor well002 Combu

Page 56

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 016Safety Important Safety, Installation, Regulatory and Warranty Requirements (contin

Page 57

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0160 Parts List (continued)Parts List0701 Hydrostat control, 3250-Plus0702 Electro wel

Page 58 - Parts List

615583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Additional Information Maintenance RecordWARNINGNeglecting to perform necessary ma

Page 59 - Parts List (continued)

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0162

Page 60

635583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service

Page 61 - Maintenance Record

Technical information subject to change without notice. Printed on environmentally friendly (recycled and recyclable) paper.Vitor

Page 62

75583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Safety Important Safety, Installation, Regulatory and Warranty Requirements (contin

Page 63

Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 018General Information About these InstructionsTake note of all symbols and notations

Page 64

95583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Product InformationSectional gray cast-iron boiler with triple-pass design.For ope