Please file in Service Binder5583 571 - 01 01/2014VITORONDr 100Vitorond 100, VR1 SeriesOil-Fired BoilerHeating input 91 to 140 MBH
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0110 Mechanical RoomGeneral InformationWhenever possible install boiler near an outsid
115583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Combustion Air Supply (continued)CodesProvisions for combustion and ventilation ai
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0112Set-upProduct DeliveryCAUTIONDo not lift or position boiler alone.Do not lift by o
135583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Set-upMinimum Clearances to CombustiblesLegendA BoilerB BurnerFor typical instal
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0114Boiler Set-up and LocationCAUTIONBoiler must be installed in such a way that oil i
155583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Connections Venting ConnectionVitorond 100The vent system must comply with all app
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0116Venting Connection (continued)ConnectionsLegendA Vitorond boiler with burnerB Ou
175583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Water Side Connections (with Hydrostat 3250-Plus Control) LegendA Boiler water sup
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0118ConnectionsSafety Connections (with Hydrostat 3250-Plus Control)Pressure relief va
195583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service ConnectionsSafety Connections (with Hydrostat 3250-Plus Control) (continued)1. T
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 012 Important Safety, Installation, Regulatory and Warranty RequirementsSafetyPlease e
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0120Connections Water Side Connections (Vitotronic Control)We recommend the installati
215583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service ConnectionsSafety Connections (Vitotronic Control)1. Install bushing/return water
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0122Connections Safety Connections (Vitotronic Control) (continued)1. To avoid probl
235583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Perform pressure test on boilerThe boiler must be leak tested before being placed
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0124FuelThis boiler is for use with the Beckett #2 fuel oil burner supplied by Viessma
255583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Beckett Burner Set-upBurner Mounting1. Remove burner from carton. The mounting f
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0126Beckett Burner Set-upOil Piping ConnectionWARNINGDo not use Teflon tape as an oil
275583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Beckett Burner Set-upElectrical Connections (with Hydrostat 3250-Plus control)Inst
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0128Beckett Burner Set-upElectrical Connections (with Hydrostat 3250-Plus control) (co
295583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Installations must follow these codes and requirements:- National Electrical Code
35583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Safety Important Safety, Installation, Regulatory and Warranty Requirements (contin
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0130Installations must follow these codesand requirements:- National Electrical Code,
315583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Beckett Burner Set-upElectrical Connections (with Vitotronic control) (continued)I
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0132Beckett Burner Set-upIMPORTANTWARNINGDo not kink capillaries. Proper operation of
335583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Installation of Vitotronic Control (continued)1. To avoid problems with removing
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0134Beckett Burner Set-upElectrical Connections (with GeniSys primary control)IMPORTAN
355583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Burner InstallationRiello Burner Set-upBurner InformationIMPORTANTRefer to the Ins
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0136Riello Burner Set-upBurner MountingRefer to the Instructions suppliedwith Riello b
375583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service IMPORTANTRefer to the Instructions suppliedwith Riello burnerWARNINGDo not use Tef
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0138Riello Burner Set-upElectrical Connections (with Hydrostat 3250-Plus control)WARNI
395583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Installations must follow these codes and requirements:- National Electrical Code
4 PageTable of Contents5583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service SafetyGeneral InformationSet-upConnectionsBecket Burner Set-
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0140Electrical Connections (with Vitotronic control)Riello Burner Set-upWARNINGElectri
415583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Electrical Connections (with Vitotronic control) (continued)Installations must fol
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0142Riello Burner Set-upWARNINGElectric shock hazard. Can cause severe personal injury
435583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service IMPORTANTWARNINGDo not kink capillaries. Proper operation of sensors is not possib
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0144Installation of Vitotronic Control1. To avoid problems with removing the top pan
455583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Initial Start-upWARNINGVerify completeness of all discussion points on the followi
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0146WARNINGDO NOT USE GASOLINE, CRANKCASE DRAININGS OR ANY OIL CONTAINING GASOLINE.Ref
475583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Start-upBeckett Burner CalibrationBoiler Model No. VR1-22 VR1-27 VR1-33Burner mode
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0148Start-upRiello Burner CalibrationIMPORTANTBoiler Model No. VR1-22 VR1-27 VR1-33Bur
495583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Start-upBarometric Draft RegulatorWhen a barometric draft regulator is used, adjus
Table of Contents5 Page5583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Start-upConnectionsServiceAdditional InformationInitial Sta
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0150 Installation Examples - HydrostatBoiler in a heating/cooling applicationCooling s
515583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Connections Installation Examples - VitotronicWithout mixing valvee.g. with Vitotr
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0152 Installation Examples - Vitotronic (continued)LegendA Heating circuitB Spring-loa
535583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service ConnectionsWith one low-temperature circuit with 4-way mixing valve, one high temp
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0154WARNINGEnsure that warning concerning fiberglass wool and ceramic fiber materials
555583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Close combustion chamber door1. Reinsert flue gas turbulators D.2. Reinstall c
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0156 Service Procedure (continued)Check heating system and domestic hot water connecti
575583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Service Service Procedure (continued)Calibrate the burnerNote: For burner technica
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0158Model No. Serial No.VR1-22 Boiler 7249048VR1-27 Boiler 7249049VR1-33 B
595583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Additional Information Parts List (continued)Parts001 5-Point sensor well002 Combu
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 016Safety Important Safety, Installation, Regulatory and Warranty Requirements (contin
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0160 Parts List (continued)Parts List0701 Hydrostat control, 3250-Plus0702 Electro wel
615583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Additional Information Maintenance RecordWARNINGNeglecting to perform necessary ma
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 0162
635583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service
Technical information subject to change without notice. Printed on environmentally friendly (recycled and recyclable) paper.Vitor
75583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Safety Important Safety, Installation, Regulatory and Warranty Requirements (contin
Vitorond 100, VR1-22 to -33 Installation and Service 5583 571 - 018General Information About these InstructionsTake note of all symbols and notations
95583 571 - 01Vitorond 100, VR1-22 to -33 Installation and Service Product InformationSectional gray cast-iron boiler with triple-pass design.For ope