Viessmann VITOCAL 300-G manuels

Manuels d'utilisation et guides de l'utilisateur pour Pompes à eau Viessmann VITOCAL 300-G.
Nous fournissons des manuels en pdf 2 Viessmann VITOCAL 300-G à télécharger gratuitement par type de document : Instructions d'exploitation, Manuel d'instructions


Table des matières

VIESMANN

1

Safety instructions

2

Installation instructions

4

Service instructions

4

Product information

9

Installation

10

Heating circuit

17

Cooling operation

19

DHW heating

20

External heat source

21

Power-OFF

22

Electrical connection

23

I>I>I>

26

With two primary pumps

27

With a common primary pump

28

Preparing for installation

30

(cont.)

30

230 V / 50 Hz

33

Low voltage

39

230 V/50 Hz

39

Two-stage heat pump cascade

41

System example 1

44

System example 2

52

230 V/50 HzLow voltage

66

Levelling the heat pump

67

Installing the heat pump

67

Remove top panel

69

< 42 V

70

Hydraulic connections

71

Installation sequence

74

Overview of connections

75

Connecting sensors

83

Connecting pumps

85

Other components

90

Cooling functions

92

Swimming pool water heating

99

Cascade control via KM BUS

100

Electrical connections

100

Power supply

103

Connecting power cables

105

Power supply with power-OFF

108

Phase monitor

113

Closing the heat pump

115

Checking grommets

116

5442 829 GB

118

Opening the heat pump

119

Writing reports

119

Commissioning assistant

121

Instructing the system user

125

Scanning messages

126

Messages

126

Message overview

127

Diagnosis (service scans)

150

Calling up diagnosis

150

Scanning operating data

150

System overview

151

Heat pump module diagnosis

154

Select with

160

Energy statement htgÜ

160

Wk. 23/09

160

Brief scan

161

Function check

163

Checking sensors

166

Checking the fuse

167

Appliance too noisy

167

Removing the heat pump module

168

Activating service menu

171

Disabling the service menu

171

7000 System scheme

173

7001 Language

173

7010 External extension

175

700A Cascade

176

5735 Number of lag heat pumps

176

7008 Swimming pool

176

700B Output of lag heat pumps

177

7017 Vitocom 100

184

5000 Enable compressor

185

5030 Heat pump output

185

Parameter group compressor

185

5130 Heat pump output

186

Parameter group compressor 2

186

6000 Set cylinder temperature

189

6015 DHW reheating

189

Parameter group DHW

189

6009 DHW start optimisation

191

600A DHW stop optimisation

192

600C Set DHW temperature 2

192

600E Temperature sensor 2

192

6016 DHW heating priority

192

7A00 Solar control unit

195

Parameter group solar

195

790A Stage at power-OFF

197

7303 Screed program

199

7203 Hysteresis

204

7204 Maximum temperature

205

7100 Cooling mode

211

Parameter group cooling

211

7101 Cooling circuit

212

Parameter group time

214

7710 LON communication module

215

Parameter group communication

215

7779 Fault manager

216

77FF Time via LON

217

8800 Lock out controls

219

Parameter group operation

219

Controller and sensor PCB

228

Parts list

231

Control parameters report

236

Hydraulic parameters report

236

Specification

241

Heat pump commissioning order

246

Declaration of conformity

247

Keyword index

248

Applicability

256

Table des matières

VITOCAL 300

1



1



1

Safety instructions

2

Applicability

3

Positioning

8

Type AW$('

10

Type BW and WW

11

Type BW and WW $('

12

Type BW$('

14

Type WW$('

18

System versions

20

System version 1

21

System version 1 $('

22

System version 2

26

System version 2 $('

27

System version 3

31

System version 3 $('

32

System version 4

36

Vitocell 333

36

System version 4 $('

37

+"

51

$(' Type BW and WW

51

System version 7 Type AW

53

$(' Type AW

58

System version 9 Type AW

67

System version 10

74

Outside temperature sensor

82

Flow temperature sensors

85

Mixer motors

86

Heating circuit pumps

87

Direct heating water heater

88

DHW heating components

89

ThreeĆway changeover valve

90

Immersion heater element EHO

91

Collector temperature sensor

92

Swimming pool sensor

93

Dew point sensor

94

Mains electrical connection

95

Keeping a service report

98

Filling the heating system

99

Switching the compressor off

100



101

Activating the remote control

102

Matching sensors

108

Checking the DHW heating

113

Diagnostic table

114

Diagnostic table $('

115

Menu structure overview

117

General overview

118

Implementing a relay test

119

Matching sensor temperatures

120

Checking signal inputs

121

;&

122

$('

122

Select the required language

127

Setting the operating mode

127

Setting the heating curve

128

Additional sensors

129

Fixed value control

131

Setting the fixed temperature

131

Number of satellites

141

Setting electrical blocking

153

Activating the second output

154

Selecting the operating mode

155

Setting the hysteresis

156

Setting DHW cylinder priority

157

Determine mixer function

161

Additional sensor

162

Setting the load rise

163

Setting the active range

165

Setting the dead range

165

Setting the phase duration

166

Phase failure relay

167

Sensor resistance curve

168

Central fault indication

169

Vitocal 300, type AW

172

Vitocal 300, type BW

174

Vitocal 300, type WW

176

Vitocal 300, type BW and WW

181

Commissioning/service reports

183

7!!1

185

$('

185

5"!

193

"!

194

-%'

197

!!'

199

Index $('

204

'9O

206

'9O9

206





Plus de produits et de manuels pour Pompes à eau Viessmann

Modèles Type de document
VITOTRONIC 300-K Manuel de service   Viessmann VITOTRONIC 300-K Technical data, 176 pages