Actual temperature dropping below
the stop temperature differential ΔToff
Exceeding the electronic temperature
limit of control unit
eZ
(max. 90 °C)
Reaching the temperature selected at
high limit safety cut-out
qW
(if installed)
Additional function for DHW heating
The requirements for the additional func-
tion are achieved through circulation
pump R5
qT
.
Suppression of DHW cylinder reheat-
ing by the boiler
Coding address "67" in boiler control unit
2
defaults a third set DHW temperature
(setting range 10 to 95 °C). This value
must be below the first set DHW temper-
ature. DHW cylinder
qP
will only be
heated by boiler
1
(solar circuit
pump R1
eE
runs) if this set value cannot
be achieved by the solar thermal sys-
tem.
DHW heating without solar energy
The upper section of DHW cylinder
qP
is
heated by boiler
1
. The cylinder ther-
mostat with cylinder temperature sen-
sor
3
of boiler control unit
2
regulates
circulation pump for cylinder heating
4
.
System examples
System example 1
(cont.)