158
Contractor
Solar contrac-
tor:
Description Delivered
condition
Setting range Set
value
Colmax cyl You can select the
consumer to which the
collector cooling func-
tion should apply (see
page 128)
1, 2, 3, 4 1 to 4
Control unit Do not adjust
HE control Do not adjust
Menu "System"
For a description of the function blocks, see page 112.
Setting values
Sys. set-
ting:
Description Deliv-
ered
condi-
tion
Setting range Set
value
Time — — — —
Date — — —
t-start Start time for the additional
function for DHW heating
(see page 136)
17:00 00:00 to 23:45
Th1on Thermostat start tempera-
ture function block 1
40 °C
−
40 to 250 °C
Th1off Thermostat stop tempera-
ture function block 1
45 °C
Th2on Thermostat start tempera-
ture function block 1
40 °C
Th2off Thermostat stop tempera-
ture function block 1
45 °C
ΔT5on Start temperature differen-
tial function block 1
5 K 1.5 to 20 K
ΔT5off Stop temperature differen-
tial function block 1
3 K 1 to 19.5 K
Appendix
Overview of system parameters
(cont.)
5414 620 GB