Viessmann VITOSOLIC 200 Instructions d'exploitation Page 89

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 172
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 88
89
Displayed faults
"Messages:"
"Fault" Cause Remedy
!Interruption
>Sensor <
The sensor has suffered a
break
Check the sensor con-
cerned (see page 92).
!Sensor circuit
>Sensor <
The sensor has suffered a
short circuit
Check the sensor con-
cerned (see page 92).
?Night circ.
Note
A central fault message
facility that may be connec-
ted to relay R7 will not be
switched ON.
Recirculation via gravity Check any installed non-
return damper (Solar-Divi-
con) or install one.
?ΔT too high
See information above.
Circulation pump faulty.
Message only if solar
heating takes place for
longer than 20 min at a
temperature differential
between collector and
consumer greater than
50 K.
Check pump connection
and pump.
!EEPROM Internal fault. Switch solar control unit
OFF and ON again after a
brief interval. Check all set-
tings. If the fault recurs,
replace the solar control
unit.
!Processors
!SD module fault Display cause of the fault:
Press OK (see
page 147).
See page 147.
SD fault
Troubleshooting
Fault messages
(cont.)
5414 620 GB
Service
Vue de la page 88
1 2 ... 84 85 86 87 88 89 90 91 92 93 94 ... 171 172

Commentaires sur ces manuels