DHW Production
17
Altering the Time Program for DHW Production
The time program consists of 4 DHW cy cles. Cycle 1 is preset at the factory from
05:30 to 22:00 hrs, i.e. domestic hot water is heated during this period.
The automatic mode is also selected, i.e. domestic hot water heating takes place
parallel to the central heating time program, but st arts 30 minutes earlier.
You have the following options to set the DHW cycles to suit your requirements:
By setting the corresponding timer cycles, domestic hot water heating can be
switched on and off up to 4 times per day.
You can set identical timer cycles for ev ery day of the week or individual timer
cycles for each day of the week.
If you require domestic hot water heating on a one time basis outside the
programmed DHW cycle, e.g. after 22.00 hrs., press
twice 2 to 3 seconds
apart.
The control unit is set up so that the
last setting change is applicable to all
heating circuits, i.e. a change of the
time program for heating circuit 1 is
also applied t o the other heating
circuits. If you require this to be
changed, please contact your heating
contractor.
When timer is programmed with --:--,
DHW production is disabled.
When timer is programmed with ON
00:00 OFF 24:00, DHW production is
possible 24 hours a day, 7 days a week.
Identical cycles for every day of the week
Automatic?
1Time prog. DHW
1 --- 7
1. Open the hinged cover on the
programming unit.
2.
for ”DHW time pro-
gram”.Waituntilthe
display shown on the left
appears.
3.
for ”Individual?”.
4.
to confirm.
5.
for ”DHW cycle 1”.
6.
for ”DHW cycle 1 ON”.
7.
/ to enter t he start of the
cycle.
8.
to confirm; the display
changes to DHW cycle
1 OFF”.
9.
/ to enter t he end of the
cycle.
10.
to confirm; the display
changes to DHW cycle
2ON.
11. TosetthestartandendofDHW
cycles 2 to 4, follow the procedure
described in points 5 to 10.
12. Close the hinged cover on the
programming unit.
If you wish to exit the time program
setting mode, press
again.
Press
to skip a timer cycle.
After you have confirmed the last
input with , the display changes
and shows the boiler water
temperature.
5303 272 v1.3