DHW Production
21
Altering the Time Program for the DHW Recirculation Pump
The time program consists of 4 timer cycles. Cycle 1 is preset at the factory from
06:00 to 22:00 hrs, i.e. the DHW recirculation pump is on during this period.
The automatic mode is also selected, i.e. the DHW recirculation pump runs parallel
to the domestic hot water heating time program.
You have the following options to set the timer cycles to suit your requirements:
By setting the corresponding timer cycles, the DHW recirculation pump can be
switched on and off up to 4 times per day.
You can set identical timer cycles for ev ery day of the week or individual timer
cycles for each day of the week.
The DHW recirculation pump should run at those times when you require hot water.
Please see the note headed ”Important” on page 16.
When timer is programmed with --:--, DHW recirculation pump is off.
When timer is programmed with ON 00:00, OFF 24:00, DHW recirculation pump
operates continuously.
Identical DHW recirculation pump cycles for every day of the week
Automatic?
1Time prog. DHW recirc.
1pump
1 --- 7
1
1 --- 7
1. Open the hinged cover on the
programming unit.
2.
for ”DHW recirc.
pump time program”.
Wait until the display
shown on the left appears.
3.
for ”Individual?”.
4.
to confirm.
5.
for ”DHW recirc.
pump cycle 1”.
6.
for ”DHW recirc.
pump cycle 1 ON.
7.
/ to enter t he start of the
cycle.
8.
to confirm; the display
changes to ” DHW recirc.
pump cycle 1 OFF”.
9.
/ to enter t he end of the
cycle.
10.
to confirm; the display
changes to ” DHW recirc.
pump cycle 2 ON.
11. TosetthestartandendoftheDHW
recirculation pump cycles 2 to 4,
follow the procedure described in
points 5 to 10.
12. Close the hinged cover on the
programming unit.
To scan the timer cycles
Follow the procedure described above,
but without using the
and
buttons.
The DHW recirculation pump cycles at a
glance
1. Open the hinged cover on the pro-
gramming unit.
2. Press
and simultaneously; the
preset time cycles appear on a time
slot graphic.
3. Close the hinged cover on the
programming unit.
If you wish to exit the time program
setting mode, press
again.
Press
to skip a timer cycle.
After you have confirmed the last
input with
, the display changes
and shows the boiler water
temperature.