Constant collector temperature
through speed control subject to the
set temperature "Tcolset".
The speed control will no longer be
influenced by the differential tempera-
ture control when this function is acti-
vated.
Make the following settings at the
solar control unit:
1. Main menu
"Solar"
"Options"
"Target temp."
Set "Yes".
2. Main menu
"Solar"
"Setting values"
"Tcolset"
Set a value.
Parallel relay
In parallel to the relay that switches the
circulation pump of a solar consumer,
relays R5 or R6 are switched, for exam-
ple for switching a diverter valve (subject
to the selected system and hydraulic
type; see from page 94).
Make the following settings at the
solar control unit:
Main menu
"Solar"
"Options"
"Par. relay"
Set "Yes".
Function description
Target temperature