157
Contractor
Solar contrac-
tor:
Description Delivered
condition
Setting range Set
value
Int time In case the interval
function has been acti-
vated:
Time when the solar
circuit pump runs
according to the selec-
ted interval and time
frame (see page 127)
30 s 5 to 500 s
Int ON In case the interval
function has been acti-
vated:
Start of the interval
function (see
page 127)
07:00
to
19:00
00:00
to
23:45
Int OFF In case the interval
function has been acti-
vated:
End of the interval
function (see
page 127)
07:00
to
19:00
00:00
to
23:45
Suppr.heat cyl In case of activated
booster suppression:
Consumer to which
this function should
apply
Cyl.1 1 to 4
HE-cylinder Consumer that is to be
heated via the external
heat exchanger
1 1 to 5
5: all consumers
Sen.HE.flow VL Sensor that should be
used for the function
"Ext. heat exchanger"
(see page 122)
3 1 to 12
Sen. bypass Sensor that should be
used for the bypass
function (see
page 119)
3 1 to 12
Bypass Bypass circuit hydraul-
ics (see page 119
and 121)
Valve Valve/pump
Appendix
Overview of system parameters
(cont.)
5414 620 GB