Viessmann VITOSOLIC 200 Instructions d'exploitation Page 79

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 172
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 78
79
1. Check whether all electrical connec-
tions have been correctly made.
2. Check that the high limit safety cut-
out and temperature limiter (if
required) are connected.
3. Switch ON the power; the solar con-
trol unit then begins an initialising
phase.
The standard display then appears
(see following diagram).
The solar control unit is now in auto-
matic mode.
Navigation through the menu
Controls
B
30.04.2009
Tcol
Tcylb
10:59
47.7 °C
35.4 °C
A
A
Standard display
The standard display will automat-
ically show after approx. 4 min, if
no adjustments are made.
B
OK key
Pressed once: Confirmation of
the menu selection
Pressed twice: Confirmation of
a value change
Calling up the main menu
Back to the standard display
from any menu
Back to the previous menu point
Terminating an adjustment
already begun (the value
reverts to its previous setting)
/ Cursor keys
Navigation through the menu
The display can only show four
lines of the menu at a time. The
arrow on the l.h. side of the display
highlights the available menu
item.
Commissioning
Switching the power ON
5414 620 GB
Service
Vue de la page 78