Operating instructions
Integral room temperature controller
Precondition: "Room temperature control" set to "Yes".
Integral proportion of the room temperature control circuit. A high value results
in a rapid response.
Access
&
"Device settings"
&
"Programming"
&
"Heating circuit"
&
"Heating circuit 1/2"
&
"Integral room temperature con-
troller" ([/])
Standard setting 100
Setting range 5 to 1000
Flow T excess
If a mixer circuit is connected (system design 4 and 6), the temperature increase
of the secondary circuit is adjusted with regard to the mixer circuit using this
function.
Access
&
"Device settings"
&
"Programming"
&
"Heating circuit"
&
"Heating circuit 2"
&
"Flow T excess"
&
(1/!)
Standard setting 0.0 K
Setting range -10 to 40.0 K
Adjusting the heating curve level and slope