Note
To prevent damage to the connecting
cables with wall clearances of
> 80 mm, the connecting cables must
be provided with strain relief on site.
1. Fit the threaded ferrule at the back
of the equipment
2. Push the drain hose onto the
threaded ferrule and secure with a
hose clip.
3. Connect the drain outlet kit with the
on-site drain connection DN 40.
Installation instructions;
drain outlet kit
4. Push the drain hose into the drain
outlet kit.
5. Note
Min. clearance between the wall
and the back of the device 45 mm.
Push the compact unit against the
wall or into the recess.
Heat pump preparation
!
Please note
If the compressor is at a steep angle in the heat pump module, the intro-
duction of lubricant into the refrigerant circuit will damage the equipment.
The heat pump module must not be tilted by more than 30° during trans-
portation.